Peter, runmqsc does not have this limitation either, nor does mqdocument (just tried it). so it looks like a buffer define problem in MS03. I suggest you contact Jeff Lowry as he is the current maintainer of MS03.
Michael www.mqsystems.com -----Original Message----- From: MQSeries List [mailto:[EMAIL PROTECTED] On Behalf Of Heggie, Peter Sent: 25 January 2008 14:21 To: [email protected] Subject: Re: Recreating a Queue Manager with MS03 SP Sorry to hijack this thread, but I've got a quick question on MS03 - it seems to truncate the startargs and stopargs values for service definitions, after 64 bytes. Am I doing something wrong? I can enter longer values in MQ Explorer and they work. Thanks, Peter Heggie -----Original Message----- From: MQSeries List [mailto:[EMAIL PROTECTED] On Behalf Of Pere Guerrero Olmedo Sent: Friday, January 25, 2008 4:48 AM To: [email protected] Subject: Re: Recreating a Queue Manager with MS03 SP Hi Hubert, so regarding your answer, if the channel connection i.e. Q1.TO.Q2 had 48 as message sequence number if I use the R option it will maintain it ? and with receivers what happens ? I don't understand very well your second answer, don't they maintain the original sequence number ? thanks !! Hubert Kleinmanns <[EMAIL PROTECTED] S.EU> Para Enviado por: [email protected] MQSeries List cc <[EMAIL PROTECTED] V.MEDUNIWIEN.AC.A Asunto T> Re: Recreating a Queue Manager with MS03 SP 25/01/2008 10:32 Por favor, responda a MQSeries List <[EMAIL PROTECTED] V.MEDUNIWIEN.AC.A T> But I think the communication partners should also reset their sender channels, otherwise I would expect, that the receiver channels have seq no 1, but the corresponding senders something else. Hubert > -----Ursprüngliche Nachricht----- > Von: MQSeries List <[email protected]> > Gesendet: 25.01.08 10:04:09 > An: [email protected] > Betreff: Re: Recreating a Queue Manager with MS03 SP > > use the -R flags: > > -R [flags] : create RESET CHANNEL commands > flags can be any combination of the follow to create RESET for > that channel > type: > s (SENDER) v (SERVER) r (RECEIVER) q (REQUESTER) c (CLUSSDR) d > (CLUSRCVR) > the default is to create RESET commands for all the above channel types > > Michael > www.mqsystems.com > > -----Original Message----- > From: MQSeries List [mailto:[EMAIL PROTECTED] On > Behalf Of > Pere Guerrero Olmedo > Sent: 25 January 2008 09:53 > To: [email protected] > Subject: Recreating a Queue Manager with MS03 SP > > Hi listers, > > after checking MS03 support pack to backup all objects of a queue > manager and after delete/define it, I've found the following problem. > > I've redefined a qmgr and later on with the file created by the > saveqmgr program I defined all objetcs. > > Till then, all ok. :-) > > The problem I didn't notice is that all channels had lost its sequence > number, so today I've seen sadly that all channels that conects to > Z/OS was > in indoubt or retrying state. After reset all channels, the situation > got solved. > > My question is, is there any trick or possibility or magic formula, to keep > all sequences numbers of channels and after redefine the channels > reset to > them ? > > > Thanks ! > > > Pere > > To unsubscribe, write to [EMAIL PROTECTED] and, in > the message body (not the subject), write: SIGNOFF MQSERIES > Instructions for managing your mailing list subscription are provided > in the Listserv General > Users Guide available at http://www.lsoft.com > Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html > > To unsubscribe, write to [EMAIL PROTECTED] and, in > the message body (not the subject), write: SIGNOFF MQSERIES > Instructions for managing your mailing list subscription are provided > in the Listserv General Users Guide available at http://www.lsoft.com > Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html > -- Hubert Kleinmanns Beratung / Schulung / Projektleitung Chairman des Arbeitskreises MQ-Series in der GSE, deutsche Region. Tel.: +49 (0) 60 78 / 7 12 21 Fax: +49 (0) 60 78 / 7 12 25 Mobil: +49 (0) 178 / 6 97 22 54 Web: www.kleinmanns.eu GSE: www.gsenet.de To unsubscribe, write to [EMAIL PROTECTED] and, in the message body (not the subject), write: SIGNOFF MQSERIES Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html To unsubscribe, write to [EMAIL PROTECTED] and, in the message body (not the subject), write: SIGNOFF MQSERIES Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html **** For your information: KeySpan is now part of National Grid.**** **************************************************************************** **** This e-mail and any files transmitted with it, are confidential to National Grid and are intended solely for the use of the individual or entity to whom they are addressed. If you have received this e-mail in error, please reply to this message and let the sender know. To unsubscribe, write to [EMAIL PROTECTED] and, in the message body (not the subject), write: SIGNOFF MQSERIES Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html To unsubscribe, write to [EMAIL PROTECTED] and, in the message body (not the subject), write: SIGNOFF MQSERIES Instructions for managing your mailing list subscription are provided in the Listserv General Users Guide available at http://www.lsoft.com Archive: http://listserv.meduniwien.ac.at/archives/mqser-l.html