I suggest that you contact MET LABS in Union City California. Their "Dust
Man" is really a good man and would probably offer you advice. I have
forgotten his name but you can reach him through Troy Franklin 888-638-9345

Don
Don Robert House, MTS
Product Certification & Regulatory Compliance
Excelsus Technologies, Inc.
2875 Loker Avenue East
Carlsbad, CA 92008-6626  USA
(760) 918-2552 Office/Lab
(760) 476-1519 FAX
URL: http://www.excelsus-tech.com




-----Original Message-----
From: Kretsch, John [mailto:john_kret...@adc.com]
Sent: Monday, September 18, 2000 8:06 AM
To: 'nebs@world.std.com'; 'EMC PSTC'; 'TREG Newsgroup'
Subject: Hygroscopic Dust Troubleshooting


I thought I would try to contact the collective on this one...

We have a shelf system that is failing GR-63 hygro dust with excessive bit
errors (unit did pass Gaseous contaminants no problem).  Air is filtered.
Anyone have experiences that they would like to share (non-proprietary of
course) about how to trouble-shoot and solve this problem?  This was the
only GR-63 test to have a failure.

Regards,
John K.