Thanks for pointing out the new model, unfortunately I can only find that 
one with Mouser but Mouser says: "Due to government regulations, Mouser is 
unable to sell this product in your country." , so I would still need your 
help in getting hold of the type with European (Swedish) prongs.

/Martin

On Saturday, 24 October 2015 17:33:22 UTC+2, taylorjpt wrote:
>
> They have been replaced by the newer tech TRG1509.  The transformer is 
> smaller as it runs at a higher frequency but the new windings still fit due 
> to the adjusted turns ratio:
>
> Model    9V    170V
> TR1509   15T   250T
> TRG1509  11T   184T
>
> The TRG1509 adds a faraday shield to the outside of the transformer but it 
> does not impact the rewinding of the secondary which is the outermost 
> winding in both models.
>
>

-- 
You received this message because you are subscribed to the Google Groups 
"neonixie-l" group.
To unsubscribe from this group and stop receiving emails from it, send an email 
to neonixie-l+unsubscr...@googlegroups.com.
To post to this group, send an email to neonixie-l@googlegroups.com.
To view this discussion on the web, visit 
https://groups.google.com/d/msgid/neonixie-l/c0839800-4a23-42cb-83b4-21718fa9846f%40googlegroups.com.
For more options, visit https://groups.google.com/d/optout.

Reply via email to