I knew Ike would have the definitive answer for the correct fuse value!

Indeed, the rectifier diodes lead a rough life as they deal with large power-on inrush surges due to charging of the large filter caps in the PSU.

I'm sure Ike does this same thing: up-size the rectifier to the highest amperage rating that will physically fit into the available space inside the unit. It also doesn't hurt to up-size the PIV (voltage) rating as well.

If the rectifier is a 4-terminal "bridge" that is bolted to the chassis, like this:

http://www.mouser.com/Search/Refine.aspx?Keyword=625-GBPC3506-E4

....be sure to apply a thin film of silicon heat sink grease on the underside of the bridge to help move heat from the bridge to the metal panel when the bridge is bolted down.

The example bridge I linked above is rated at 35 Amps. I believe I've seen rectifiers in that same package rated at 40 Amps or more.

Best,

Bri



On 4/19/2011 21:03, Ike wrote:
Hi all,
The correct mains fuse value for a stock PS-3 is 5 amp slow-blow, as
Brian says. I THINK that the Sytek rebuilt units have up rated
transformers which could account for the 7 amp fuse on your spare
supply. If the fuse has vaporized, the most likely culprit is a failed
bridge rectifier. Any competent tech should be able to replace it.
Best
Ike

Ike Zimbel
Zimbel Audio Ltd
416-720-0887
www.zimbelaudio.com <http://www.zimbelaudio.com>
Sent from my iPhone

On 2011-04-19, at 9:44 PM, Tommy Mokas <[email protected]
<mailto:[email protected]>> wrote:

Thanks for the response Brian. Well, the fuse is definitely blown,
which is disheartening at this hour...but alas, I'm going to go get
more fuses right now, and I'll report back soon. Hopefully its
something simple, although I'm doubting it is for some reason. Anybody
have a neotek tech in NYC, in case I need to make that call?

On Tue, Apr 19, 2011 at 9:05 PM, Brian Roth
<<mailto:[email protected]>[email protected]
<mailto:[email protected]>> wrote:

    If the inside of the glass tube of the fuse has black "crap" blown
    all over, that sounds as if there is a short circuit somewhere
    inside the power supply. But, if the wire link inside is merely
    broken, it could be a case of "who knows?"

    I don't have schemos for that unit, so I can't say whether 5 or 7
    Amps is correct. It almost certainly needs to be a slow-blow type.
    I think you will be OK trying a 5A slow-blow in there to see if it
    blows again. If it blows again, STOP and have the PSU serviced. If
    the fuse holds and the desk works, the next step would be to see
    if 7A is actually the correct value, which could explain the blown 5A.

    Best,

    Bri




    On 4/19/2011 19:09, Tommy Mokas wrote:

        Hello Neoteks,

        Quick question, if the fuse on the back of the power supply blows,
        what should be my main concerns? There was no other reason for
        me to
        believe that the power supply wasn't functioning correctly
        until my
        biz partner went to turn it on and it didn't power up. I just
        got back
        into town to find a blown fuse in the back.

        The fuse that was in it was a 5A 250V 3/3. However I have a backup
        power supply (which I've never needed) that has a sticker
        indicating a
        7a fuse. I assume this referring to amps, but I want to be
        sure. Is it
        possible that the other power supply (which apparently serviced in
        '96) has a changed value on this particular fuse? Is that a
        mod done
        to these?

        And for my final question, am I risking the power supply by
        putting
        the same fuse in only to have it blow again? I don't want to
        do any
        more damage but I do have work to do :). Any insight is really
        appreciated, especially if you're a night owl such as myself.
        Thanks
        so much!

        Best,
        Tommy Mokas
        Casa Nova Studios
        <http://www.twitter.com/tommymokas>www.twitter.com/tommymokas
        <http://www.twitter.com/tommymokas>
        <<http://www.twitter.com/tommymokas>http://www.twitter.com/tommymokas>
        <http://www.twitter.com/casanovastudios>www.twitter.com/casanovastudios
        <http://www.twitter.com/casanovastudios>
        
<<http://www.twitter.com/casanovastudios>http://www.twitter.com/casanovastudios>




        No virus found in this incoming message.
        Checked by AVG - <http://www.avg.com>www.avg.com
        <http://www.avg.com>
        Version: 9.0.894 / Virus Database: 271.1.1/3582 - Release
        Date: 04/18/11 09:22:00

    ------

    View the list online at:
    
<http://www.mail-archive.com/[email protected]>http://www.mail-archive.com/[email protected]

    You can unsubscribe at anytime by sending an email to
    mailto:<mailto:[email protected]>[email protected]
    <mailto:[email protected]> with "unsubscribe neotek" in the
    message body. If you have any difficulties, or questions --please
    send an email to
    mailto:<mailto:[email protected]>[email protected]
    <mailto:[email protected]>.

    The Neotek list is lovingly hosted by Catapult Web. Remember that
    any message or reply sent to the list will be automatically
    forwarded to all subscribers.

    Vive Le Neotek!

    Thanks.





No virus found in this incoming message.
Checked by AVG - www.avg.com
Version: 9.0.894 / Virus Database: 271.1.1/3582 - Release Date: 04/18/11 
09:22:00

------

View the list online at: http://www.mail-archive.com/[email protected]

You can unsubscribe at anytime by sending an email to mailto:[email protected] with 
"unsubscribe neotek" in the message body. If you have any difficulties, or 
questions --please send an email to mailto:[email protected].

The Neotek list is lovingly hosted by Catapult Web. Remember that any message 
or reply sent to the list will be automatically forwarded to all subscribers.

Vive Le Neotek!

Thanks.

Reply via email to