On Monday, September 15, 2014 5:52 PM, Edward d'Auvergne <[email protected]> 
wrote:
  


Hi Arun,

Welcome to the NESSY mailing lists!  You may remember
 me from
elsewhere 
(http://thread.gmane.org/gmane.science.nmr.relax.user/1744/focus=1763).
I am the lead developer of the relax project (and minfx
https://gna.org/projects/minfx/and bmrblib
https://gna.org/projects/bmrblib/), as well as the maintainer of
Michael Bieri's NESSY software.  Note that NESSY is in a hibernation
state until another developer wishes to advance the software.  As I am
only the maintainer and do not know the source code so well, I may not
be able to solve all your problems.  I'll do what I can though.

Note that for the public mailing lists, it is often better to sign up
for them.  That way your messages will be automatically accepted and
you will receive replies from all NMR spectroscopists signed up to the
list, as sometimes they only reply to the list and not original
author.  I also only just saw your message sitting between a large
pile of spam, waiting to be accepted.

For any error you see or problem you have, could you explain in detail
what you did?  There is not enough information for me to work out what
the problem is.  I.e. give a step-by-step explanation of how to
trigger the problem, so that I can repeat these steps and see the
problem for myself.  For example I have just searched the entire NESSY
source code
 tree and cannot find the word 'downloaded'.  Are you sure
that that was what the error message was?  Note that you can also
submit bugs using the link
https://gna.org/bugs/?func=additem&group=nessy. relax has a similar
bug tracker.

Regards,

Edward


On 10 September 2014 18:07, Arun Gupta <[email protected]> wrote:
> Hi
>
> I am a new user and was looking forward to run the project files before my
> CPMG dispersion data. But always  error comes that  " project file couldn't
> be downloaded " .  I have installed " Nessy" on my Windows8 64 bit operating
> system.  Looking forward for the solution
>
>
> Arun Gupta
>
> _______________________________________________
> Nessy-users mailing list
> [email protected]
> https://mail.gna.org/listinfo/nessy-users

>


   
Hi
 
Thanks for your reply. The error message is reported when I try to download the 
project files  on my computer as template files . However  I input my N15 
relaxation dispersion data of Sparky peak list files  to Nessy. The input of 
data
was fine and the evaluation of data files and data analysis went well . But in 
my version of nessy graphical user interface I couldn't find option for 
selection of different peak list formats,  seems like somehow it has  inbuilt 
set  up for Sparky peaklists only.    Another important option  which I found 
is the analysis of HD-exchange data in nessy  but the limitation of data set to 
30 doesn't help much for analysis of data set of 150 HSQCs which I have 
acquired for a larger period of time. Can we input this much big data set in 
Nessy . 
 
Looking forward for your suggestions
 
Regards
 
Arun 
_______________________________________________
Nessy-users mailing list
[email protected]
https://mail.gna.org/listinfo/nessy-users