Thanks Magnus, It works now with the new MIB file.

-Zimmer

On Sun, Apr 3, 2011 at 6:56 PM, Magnus Fromreide <[email protected]>wrote:

> On Sun, 2011-04-03 at 08:33 -0400, Zimmer Hu wrote:
> > Hi,
> >
> > I'm a beginner in netsnmp, and working on table right now. I get
> > hindered in tabel loading.
> >
> > I have made a very simple table MIB file (see attachment). This MIB
> > file has passed the compilation of unbrowse
> > (http://www.unleashnetworks.com) so it is compliant with MIB standard
> > in some way.
>
> Possibly, but not compliant enough.
>
> $ smilint /tmp/MyTable-MIB.my
> /tmp/MyTable-MIB.my:7: syntax error, unexpected MODULE_IDENTITY, expecting
> FROM or ','
>
> This means you are missing a semicolon after the imports.
> Adding that and rechecking gives
>
> $ smilint /tmp/MyTable-MIB.my
> /tmp/MyTable-MIB.my:16: warning: date specification `201108130800Z' is in
> the future
> /tmp/MyTable-MIB.my:16: revision date after last update
> /tmp/MyTable-MIB.my:19: revision for last update is missing
> /tmp/MyTable-MIB.my:26: syntax error, unexpected LOWERCASE_IDENTIFIER,
> expecting UPPERCASE_IDENTIFIER
> /tmp/MyTable-MIB.my:30: illegal character `�' (0xe2) in quoted string
> /tmp/MyTable-MIB.my:30: illegal character `�' (0x80) in quoted string
> /tmp/MyTable-MIB.my:30: illegal character `�' (0xa6) in quoted string
> /tmp/MyTable-MIB.my:31: warning: flushing recent incorrect declaration, see
> previous error(s)
> /tmp/MyTable-MIB.my:35: syntax error, unexpected LOWERCASE_IDENTIFIER
> /tmp/MyTable-MIB.my:39: illegal character `�' (0xe2) in quoted string
> /tmp/MyTable-MIB.my:39: illegal character `�' (0x80) in quoted string
> /tmp/MyTable-MIB.my:39: illegal character `�' (0xa6) in quoted string
> /tmp/MyTable-MIB.my:40: warning: flushing recent incorrect declaration, see
> previous error(s)
> /tmp/MyTable-MIB.my:41: syntax error, unexpected COLON_COLON_EQUAL
> /tmp/MyTable-MIB.my:41: warning: flushing recent incorrect declaration, see
> previous error(s)
> /tmp/MyTable-MIB.my:44: syntax error, unexpected COLON_COLON_EQUAL,
> expecting OBJECT
> /tmp/MyTable-MIB.my:47: warning: flushing recent incorrect declaration, see
> previous error(s)
> /tmp/MyTable-MIB.my:60: warning: use Integer32 instead of INTEGER in SMIv2
> /tmp/MyTable-MIB.my:56: unknown object identifier label `myTableEntry'
> /tmp/MyTable-MIB.my:58: warning: node `myStatus' must be contained in at
> least one conformance group
> /tmp/MyTable-MIB.my:4: warning: identifier `NOTIFICATION-TYPE' imported
> from module `SNMPv2-SMI' is never used
>
> So I'd say you have some work to do.
>
> You can download smilint from
> http://www.ibr.cs.tu-bs.de/projects/libsmi/download.html
>
> /MF
>
>

Attachment: MYTABLE-MIB.my
Description: Binary data

------------------------------------------------------------------------------
Create and publish websites with WebMatrix
Use the most popular FREE web apps or write code yourself; 
WebMatrix provides all the features you need to develop and 
publish your website. http://p.sf.net/sfu/ms-webmatrix-sf
_______________________________________________
Net-snmp-coders mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/net-snmp-coders

Reply via email to