On 23/04/07, [EMAIL PROTECTED] <[EMAIL PROTECTED]> wrote:
> Still no canaries singing. It doesn't like --with-mibs="+DELL-CMC-MIB",
> it's trying to find a MIB with a plus in the name.
Bother!
> I'm going to have to
> specify the whole set we want to load.
Can I suggest an alternative...
If you're implementing a particular MIB module, then try adding the line
config_add_mib( DELL-CMC-MIB )
to the header file for this module. (Note, there is no trailing ';')
If you're not implementing this module, try adding the same line
to 'agent/mibgroup/default_modules.h' instead.
Dave
-------------------------------------------------------------------------