On 12/22/2017 02:31 PM, Faiz Abbas wrote:
> From: Franklin S Cooper Jr <fcoo...@ti.com>
> 
> Various CAN or CAN-FD IP may be able to run at a faster rate than
> what the transceiver the CAN node is connected to. This can lead to
> unexpected errors. However, CAN transceivers typically have fixed
> limitations and provide no means to discover these limitations at
> runtime. Therefore, add support for a can-transceiver node that
> can be reused by other CAN peripheral drivers to determine for both
> CAN and CAN-FD what the max bitrate that can be used. If the user
> tries to configure CAN to pass these maximum bitrates it will throw
> an error.

Please add support to read the maximum bitrate via netlink. Have a look
at 12a6075cabc0 ("can: dev: add CAN interface termination API"). I think
you need to extend the following functions: can_get_size() and
can_fill_info().

Marc

-- 
Pengutronix e.K.                  | Marc Kleine-Budde           |
Industrial Linux Solutions        | Phone: +49-231-2826-924     |
Vertretung West/Dortmund          | Fax:   +49-5121-206917-5555 |
Amtsgericht Hildesheim, HRA 2686  | http://www.pengutronix.de   |

Attachment: signature.asc
Description: OpenPGP digital signature

Reply via email to