On 10/01/10 01:29, Francisco Jerez wrote:
Grzesiek Sójka<p...@pfu.pl> writes:
On 09/30/10 18:05, Francisco Jerez wrote:
Does the following command help?
$ xrandr --output DVI-I-2 --set "scaling mode" "None"
Yes! Now I have:
xrandr --output DVI-I-1 --set "scaling mode" "None"
xrandr --output DVI-I-2 --set "scaling mode" "None"
in xinitrc. Both displays work fine when Xserver is running. But after I
go back to the console the display #1 switches off and #2 starts to
blink again. Is it possible to fix the console??
Do you need to tell the binary driver to do anything special to get it
working on those monitors? (e.g. manually specified timings or EDID)
No, binary driver works fine without any extra settings. The version I
used was 173.14.22. With nouveau drivers I'm forced to use the following
Modeline "1600x1200_def" 144 1600 1628 1788 1920 1200 1201 1204 1250
Without it the displays (both) are blinking. Remember that binary nvidia
claims that the MaxPixClk is 135MHz and nouveau says that it is 175MHz.
According to the spec it should be 162MHz. I'm not sure but I think that
this high rate works only with D-SUB. Actually I have 3 monitors and the
third one is connected with the ancient Matrox Millennium II card using
the D-SUB cable and it uses the modeline with the 162MHz PixClk.
PS. By the way - I was force to install Win7 and it works with my LCD
without any drivers installed.
_______________________________________________
Nouveau mailing list
Nouveau@lists.freedesktop.org
http://lists.freedesktop.org/mailman/listinfo/nouveau