Enrico,

If I remember correctly, your Arista switches are sending sFlow. So please
try to add nProbe option* --upscale-traffic* that will adjust the traffic
on the basis of sFlow sampling rates.

Simone

On Thu, Jun 8, 2017 at 10:52 AM, Enrico Kern <enrico.k...@glispamedia.com>
wrote:

> Hi all,
>
> yesterday i upgraded our ntop and nprobe from 2.5 to 3.1. Now it shows
> absolute wrong traffic numbers. As example we have machines constantly
> doing 4 to 10 gbit/s and all it shows now for all hosts is 2 kbit/s up to 1
> Mbit/s thats all.
>
> We use normal nprobe where our arista switches send data too as it was
> before with 2.5
>
> nprobe --zmq tcp://*:5557 -i none --collector-port 6343 --verbose 2
> --dump-stats
>
>
> We had issues with 2 before with wrong traffic and arista switches which
> was solved after reporting that to the list.
>
> --
>
> Enrico Kern
>
> Lead System Engineer
>
> glispa GmbH
> Sonnenburger Straße 73
> 10437 Berlin, Germany
>
> tel: +49 30 5557130-17 <+49%2030%20555713017>
>
> mobile: +49 152 26814501
>
> skype: flyersaenrico.k...@glispamedia.comwww.glispa.com
>
> __________________________________________
> Sitz Berlin, AG Charlottenburg HRB 114678B
>
>
> _______________________________________________
> Ntop mailing list
> Ntop@listgateway.unipi.it
> http://listgateway.unipi.it/mailman/listinfo/ntop
>
_______________________________________________
Ntop mailing list
Ntop@listgateway.unipi.it
http://listgateway.unipi.it/mailman/listinfo/ntop

Reply via email to