We have longevity test bringing up & down 200 switches continuously so we have 
not observed this particular issue. Does your issue reproduce consistently? Can 
you open a bug and upload the karaf log?

> On Mar 24, 2016, at 3:17 AM, Saibal Roy <[email protected]> wrote:
> 
> Hi All,
>  
> I was testing the Longevity test using OVS 2.3.2 and connecting 120 switches 
> across the cluster(40 per controller) using latest  Be Code with He Plugin.
>  
> I could see that  118 switches are connected and 2 switches are disconnected 
> if I run it for overnight(8 hours).
>  
> Has someone encountered this Longevity issue earlier? Or will I raise a BUG 
> for this.
>  
> Thanks & Regards,
> Saibal Roy.
>  
>  
> _______________________________________________
> openflowplugin-dev mailing list
> [email protected] 
> <mailto:[email protected]>
> https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev 
> <https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev>
_______________________________________________
openflowplugin-dev mailing list
[email protected]
https://lists.opendaylight.org/mailman/listinfo/openflowplugin-dev