--On Thursday, April 07, 2016 9:22 PM +0000 [email protected] wrote: > Quanah, > > Before I put any time into putting together a patch for syncrepl.c, I > listened to what you said was generally recommended. I added the > syncprov overlay to the consumer, even though it will never be a > provider. I found that with the syncprov overlay after the syncrepl > overlay in the config file, the DSA's CSN will still get out of sync. > However, with the syncprov overlay before the syncrepl overlay - I have > been running for the last three hours without any reports of the DSA's > CSN being wrong on the replica (with one exception that was a check in > the middle of an update and did not coincide with the missing csn value > in the logs). > > Therefore, I'm going to develop a doc patch to fix the guide and man > pages rather than a code patch.
Hi Frank, Great to hear!!! I knew there was a reason behind doing so... I've done so for years, but the exact reasons behind it have drifted into the fog of time. I did recall it was related to CSNs though, so thought that this might be it. --Quanah -- Quanah Gibson-Mount Platform Architect Zimbra, Inc. -------------------- Zimbra :: the leader in open source messaging and collaboration A division of Synacor, Inc