Hi,

Hendrik Sattler schrieb:
> That's what I already mentioned some time ago when we fixed NewSiemens Obex 
> mode:
>  wait one second after last sent/received bit
>  send "+++"
>  wait at least one second
>   
I'll try that asap. Sergey, thanks for the prompt hint!

> I don't know about the BFB(0x81 0x00 0x03) command,
Well Siefs works and Dmitry is a really nice guy (and he helped a lot
with BFB development), but that is exactly the kind of code grandma
warned us about... it's not BFB but plain textbook OBEX DISCONNECT :)

> trunk/multicobex/multi_cobex.c line 68:
> c->type can be either CT_BFB _or_ CT_SIEMENS, both need the same sequence, 
> IIRC.
>   
BFB needs (read: works best with) a wrapped AT^SQWE. SIEMENS on the
other hand is the transparent mode and needs (mostly likely) the
wait-"+++"-wait mentioned above.


regards,
Christian

-------------------------------------------------------------------------
This SF.net email is sponsored by: Splunk Inc.
Still grepping through log files to find problems?  Stop.
Now Search log events and configuration files using AJAX and a browser.
Download your FREE copy of Splunk now >> http://get.splunk.com/
_______________________________________________
Openobex-users mailing list
[email protected]
http://lists.sourceforge.net/lists/listinfo/openobex-users