Hi, Hendrik Sattler schrieb: > That's what I already mentioned some time ago when we fixed NewSiemens Obex > mode: > wait one second after last sent/received bit > send "+++" > wait at least one second > I'll try that asap. Sergey, thanks for the prompt hint!
> I don't know about the BFB(0x81 0x00 0x03) command, Well Siefs works and Dmitry is a really nice guy (and he helped a lot with BFB development), but that is exactly the kind of code grandma warned us about... it's not BFB but plain textbook OBEX DISCONNECT :) > trunk/multicobex/multi_cobex.c line 68: > c->type can be either CT_BFB _or_ CT_SIEMENS, both need the same sequence, > IIRC. > BFB needs (read: works best with) a wrapped AT^SQWE. SIEMENS on the other hand is the transparent mode and needs (mostly likely) the wait-"+++"-wait mentioned above. regards, Christian ------------------------------------------------------------------------- This SF.net email is sponsored by: Splunk Inc. Still grepping through log files to find problems? Stop. Now Search log events and configuration files using AJAX and a browser. Download your FREE copy of Splunk now >> http://get.splunk.com/ _______________________________________________ Openobex-users mailing list [email protected] http://lists.sourceforge.net/lists/listinfo/openobex-users