Hi, Am 22.01.2014 13:52, schrieb Spencer Oliver: > On 22 January 2014 11:44, Peter Stuge <pe...@stuge.se> wrote: >> ger...@openocd.zylin.com wrote: >>> cfg: LPC17xx default to using SYSRESETREQ to reset target >>> >>> Originally the LPC17xx user guide (UM10360 Rev 2) stated that >>> SYSRESETREQ >>> was not supported, so this was the default cortex_m reset mode. >>> >>> Rev 3 of the same user guide states that it is now supported. >> Is there some lpc17xx errata documentation on the topic, or was it >> always just a documentation error? >>
Looks like an error in the documentation. It was never mentioned in the errata sheet. > It was a note in the main user guide (rev2) - > "This is intended to force a large system reset of all major > components except for debug. Note: support for > SYSRESETREQ is not included in LPC17xx devices." > > I never tested it before as i have only just got access to a lpc17xx, > and if the user has srst connected then this does not matter anyway. I was almost sure it did not work before, but I tested it just now on my Hitex LPC1768 Stick and it worked. This older stick has the initial revision of the LPC1768 with the RTC bug. -- J. Fischer ------------------------------------------------------------------------------ CenturyLink Cloud: The Leader in Enterprise Cloud Services. Learn Why More Businesses Are Choosing CenturyLink Cloud For Critical Workloads, Development Environments & Everything In Between. Get a Quote or Start a Free Trial Today. http://pubads.g.doubleclick.net/gampad/clk?id=119420431&iu=/4140/ostg.clktrk _______________________________________________ OpenOCD-devel mailing list OpenOCD-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/openocd-devel