could this be the issue?

[EMAIL PROTECTED]:/tmp/x86_64# fmadm faulty
--------------- ------------------------------------  -------------- ---------
TIME            EVENT-ID                              MSG-ID         SEVERITY
--------------- ------------------------------------  -------------- ---------
May 10 02:47:44 2a393307-6f8a-e660-9221-a170c4d92505  PCIEX-8000-0A  Critical 

Fault class : fault.io.pciex.device-interr
Affects     : dev:////[EMAIL PROTECTED],0/pci8086,[EMAIL 
PROTECTED]/pci8086,[EMAIL PROTECTED]/pci8086,[EMAIL PROTECTED]/pci8086,[EMAIL 
PROTECTED],1
                  degraded but still in service
FRU         : "MB" 
(hc://:product-id=S5000PAL.:chassis-id=.........:server-id=fab40/motherboard=0)
                  faulty

Description : A problem was detected for a PCIEX device.
              Refer to http://sun.com/msg/PCIEX-8000-0A for more information.

Response    : One or more device instances may be disabled

Impact      : Loss of services provided by the device instances associated with
              this fault

Action      : Schedule a repair procedure to replace the affected device.  Use
              fmdump -v -u <EVENT_ID> to identify the device or contact Sun for
              support.


affects  pci8086,[EMAIL PROTECTED],1 degraded but still in service .. which is 
the disks,,,

        pci8086,346c, instance #0 (driver name: ahci)
            disk, instance #0 (driver name: sd)
            disk, instance #1 (driver name: sd)
 
 
This message posted from opensolaris.org