On Fri, 2014-06-20 at 11:49 +0200, Andreas Lauser wrote:

> [i]f MULTX- is not specified, do the values specified in MULTX also
> apply for the negative direction?

No, they do not.  If MULTX- is not explicitly defined in the input, the
format requires that MULTX- be implicitly assigned an all-ones array.
In other words, the multiplier in this case is exactly equal to the
MULTX value of the connection's "left" cell.


Bård