Hi Ales, thanks for the test. On Thu, Feb 5, 2026 at 7:12 AM Ales Musil via dev <[email protected]> wrote: > > Add a test that should ensure that two controllers running next to > each other do not touch zones from different range then the one
s/then/than/ > assigned to them. > > Reported-at: https://issues.redhat.com/browse/FDP-2084 > Signed-off-by: Ales Musil <[email protected]> > --- > tests/ovn.at | 153 +++++++++++++++++++++++++++++++++++++++++++++++++++ > 1 file changed, 153 insertions(+) > > diff --git a/tests/ovn.at b/tests/ovn.at > index d7f173c90..1c33cae57 100644 > --- a/tests/ovn.at > +++ b/tests/ovn.at > @@ -44562,3 +44562,156 @@ check ovn-nbctl --wait=hv lsp-set-type down_ext > localnet > OVN_CLEANUP([hv1],[hv2]) > AT_CLEANUP > ]) > + > +# NOTE: This test case runs two ovn-controllers inside the same sandbox > (hv1). > +# Each controller uses a unique chassis name - hv1 and hv2 - and manage > +# different bridges with different ports. This is why all 'as' commands below > +# are executed from the same - hv1 - sandbox, regardless of whether they > +# logically belong to ports of chassis named hv1 or hv2. Is it possible to give the sandbox a name that is independent from the two chassis? Maybe call the sandbox "hv1" and the two ovn-controller chassis "virt-chassis-1" and "virt-chassis-2"? > +OVN_FOR_EACH_NORTHD([ > +AT_SETUP([multiple controllers on the same host doesn't have CT conflict]) > +ovn_start > +net_add n1 > + > +sim_add hv1 > +as hv1 > +ovs-vsctl add-br br-phys-1 > +ovn_attach n1 br-phys-1 192.168.0.1 24 > + > +ovs-vsctl add-br br-phys-2 > + > +ovn-appctl vlog/set vconn:dbg > + > +check ovs-vsctl \ > + -- set Open_vSwitch . external-ids:ct-zone-range-hv1=100-199 \ > + -- set Open_vSwitch . external-ids:ct-zone-range-hv2=300-399 > + > +check ovn-nbctl ls-add ls > + > +check ovn-nbctl lsp-add ls lsp1 > +check ovn-nbctl lsp-add ls lsp2 > + > +check ovn-nbctl lsp-set-addresses lsp1 "00:00:00:00:00:10 10.0.0.10" \ > + -- lsp-set-options lsp1 requested-chassis=hv1 > +check ovn-nbctl lsp-set-addresses lsp2 "00:00:00:00:00:20 10.0.0.20" \ > + -- lsp-set-options lsp2 requested-chassis=hv2 > + > +check ovn-nbctl lr-add lr1 -- set Logical_Router lr1 options:chassis=hv1 > +check ovn-nbctl lrp-add lr1 lr1-ls 00:00:00:00:00:01 10.0.0.1/24 > +check ovn-nbctl lsp-add-router-port ls ls-lr1 lr1-ls > + > +check ovn-nbctl lr-add lr2 -- set Logical_Router lr2 options:chassis=hv2 > +check ovn-nbctl lrp-add lr2 lr2-ls 00:00:00:00:00:01 10.0.0.1/24 > +check ovn-nbctl lsp-add-router-port ls ls-lr2 lr2-ls > + > +check ovs-vsctl -- add-port br-int vif1 -- \ > + set interface vif1 external-ids:iface-id=lsp1 > + > +wait_for_ports_up lsp1 > +check ovn-nbctl --wait=hv sync > + > +# the file is read once at startup so it's safe to write it > +# here after the first ovn-controller has started > +echo hv2 > ${OVN_SYSCONFDIR}/system-id-override > + > +# for some reason SSL/TLS ovsdb configuration overrides CLI, so > +# delete ssl config from ovsdb to give CLI arguments priority > +ovs-vsctl del-ssl > + > +start_virtual_controller n1 br-phys-2 br-int-2 192.168.2.1 24 geneve hv2 \ > + --pidfile=${OVS_RUNDIR}/ovn-controller-2.pid \ > + --log-file=${OVS_RUNDIR}/ovn-controller-2.log \ > + -p $PKIDIR/testpki-hv2-privkey.pem \ > + -c $PKIDIR/testpki-hv2-cert.pem \ > + -C $PKIDIR/testpki-cacert.pem \ > + -vvconn:dbg > +pidfile="$OVS_RUNDIR"/ovn-controller-2.pid > +on_exit "test -e \"$pidfile\" && kill \`cat \"$pidfile\"\`" > + > +check ovs-vsctl -- add-port br-int-2 vif2 -- \ > + set interface vif2 external-ids:iface-id=lsp2 > + > +wait_for_ports_up lsp2 > +check ovn-nbctl --wait=hv sync > +OVN_POPULATE_ARP > + > +check_zone_allocation() { > + local ctl=$1 > + local prefix=$2 > + > + AT_CHECK_UNQUOTED([ovn-appctl -t $ctl ct-zone-list | cut -d ' ' -f2 | > grep -vE "$prefix[[0-9]]{2}"], [1]) > +} > + > +check_zone_flush() { > + local file=$1 > + local prefix=$2 > + > + AT_CHECK_UNQUOTED([grep NXT_CT_FLUSH_ZONE ${OVS_RUNDIR}/$file | grep -vE > "zone_id=$prefix[[0-9]]{2}"], [1]) > +} > + > +hv1_ctl="${OVS_RUNDIR}/ovn-controller.$(cat > ${OVS_RUNDIR}/ovn-controller.pid).ctl" > +hv2_ctl="${OVS_RUNDIR}/ovn-controller.$(cat > ${OVS_RUNDIR}/ovn-controller-2.pid).ctl" > + > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +# Re-bind both LSPs > +check ovs-vsctl set interface vif1 external-ids:iface-id=lsp2 \ > + -- set interface vif2 external-ids:iface-id=lsp1 > +check ovn-nbctl lsp-set-options lsp1 requested-chassis=hv2 \ > + -- lsp-set-options lsp2 requested-chassis=hv1 > +wait_for_ports_up > +check ovn-nbctl --wait=hv sync > + > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +# Swap GW routers. > +check ovn-nbctl set Logical_Router lr1 options:chassis=hv2 \ > + -- set Logical_Router lr2 options:chassis=hv1 > +check ovn-nbctl --wait=hv sync > + > +# Do recompute for both controller to make that datapath swap effective. > +check ovn-appctl -t $hv1_ctl inc-engine/recompute > +check ovn-appctl -t $hv2_ctl inc-engine/recompute > + > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +# Remove LSPs. > +check ovn-nbctl --wait=hv lsp-del lsp1 > + > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +check ovn-nbctl --wait=hv lsp-del lsp2 > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +# Make the routers distributed again. > +check ovn-nbctl remove Logical_Router lr1 options chassis > +check ovn-nbctl remove Logical_Router lr2 options chassis > +check ovn-nbctl --wait=hv sync > + > +# Do recompute for both controller to make that datapath remove effective. > +check ovn-appctl -t $hv1_ctl inc-engine/recompute > +check ovn-appctl -t $hv2_ctl inc-engine/recompute > + > +check_zone_allocation $hv1_ctl 1 > +check_zone_flush ovn-controller.log 1 > +check_zone_allocation $hv2_ctl 3 > +check_zone_flush ovn-controller-2.log 3 > + > +OVN_CLEANUP([hv1]) > +AT_CLEANUP > +]) > -- > 2.52.0 > > _______________________________________________ > dev mailing list > [email protected] > https://mail.openvswitch.org/mailman/listinfo/ovs-dev > _______________________________________________ dev mailing list [email protected] https://mail.openvswitch.org/mailman/listinfo/ovs-dev