On Mon, Feb 9, 2026 at 4:44 PM Mark Michelson <[email protected]> wrote:

> Hi Ales, thanks for the test.
>

Hi Mark,

thank you for the review.


>
> On Thu, Feb 5, 2026 at 7:12 AM Ales Musil via dev
> <[email protected]> wrote:
> >
> > Add a test that should ensure that two controllers running next to
> > each other do not touch zones from different range then the one
>
> s/then/than/
>
> > assigned to them.
> >
> > Reported-at: https://issues.redhat.com/browse/FDP-2084
> > Signed-off-by: Ales Musil <[email protected]>
> > ---
> >  tests/ovn.at | 153 +++++++++++++++++++++++++++++++++++++++++++++++++++
> >  1 file changed, 153 insertions(+)
> >
> > diff --git a/tests/ovn.at b/tests/ovn.at
> > index d7f173c90..1c33cae57 100644
> > --- a/tests/ovn.at
> > +++ b/tests/ovn.at
> > @@ -44562,3 +44562,156 @@ check ovn-nbctl --wait=hv lsp-set-type
> down_ext localnet
> >  OVN_CLEANUP([hv1],[hv2])
> >  AT_CLEANUP
> >  ])
> > +
> > +# NOTE: This test case runs two ovn-controllers inside the same sandbox
> (hv1).
> > +# Each controller uses a unique chassis name - hv1 and hv2 - and manage
> > +# different bridges with different ports. This is why all 'as' commands
> below
> > +# are executed from the same - hv1 - sandbox, regardless of whether they
> > +# logically belong to ports of chassis named hv1 or hv2.
>
> Is it possible to give the sandbox a name that is independent from the
> two chassis? Maybe call the sandbox "hv1" and the two ovn-controller
> chassis "virt-chassis-1" and "virt-chassis-2"?
>

I'm afraid not, at least not without rewriting the ovn_attach
(ovn_az_attach) helpers. Which I'm not sure is worth doing for
4 tests that use this technique.


> > +OVN_FOR_EACH_NORTHD([
> > +AT_SETUP([multiple controllers on the same host doesn't have CT
> conflict])
> > +ovn_start
> > +net_add n1
> > +
> > +sim_add hv1
> > +as hv1
> > +ovs-vsctl add-br br-phys-1
> > +ovn_attach n1 br-phys-1 192.168.0.1 24
> > +
> > +ovs-vsctl add-br br-phys-2
> > +
> > +ovn-appctl vlog/set vconn:dbg
> > +
> > +check ovs-vsctl \
> > +    -- set Open_vSwitch . external-ids:ct-zone-range-hv1=100-199 \
> > +    -- set Open_vSwitch . external-ids:ct-zone-range-hv2=300-399
> > +
> > +check ovn-nbctl ls-add ls
> > +
> > +check ovn-nbctl lsp-add ls lsp1
> > +check ovn-nbctl lsp-add ls lsp2
> > +
> > +check ovn-nbctl lsp-set-addresses lsp1 "00:00:00:00:00:10 10.0.0.10" \
> > +    -- lsp-set-options lsp1 requested-chassis=hv1
> > +check ovn-nbctl lsp-set-addresses lsp2 "00:00:00:00:00:20 10.0.0.20" \
> > +    -- lsp-set-options lsp2 requested-chassis=hv2
> > +
> > +check ovn-nbctl lr-add lr1 -- set Logical_Router lr1 options:chassis=hv1
> > +check ovn-nbctl lrp-add lr1 lr1-ls 00:00:00:00:00:01 10.0.0.1/24
> > +check ovn-nbctl lsp-add-router-port ls ls-lr1 lr1-ls
> > +
> > +check ovn-nbctl lr-add lr2 -- set Logical_Router lr2 options:chassis=hv2
> > +check ovn-nbctl lrp-add lr2 lr2-ls 00:00:00:00:00:01 10.0.0.1/24
> > +check ovn-nbctl lsp-add-router-port ls ls-lr2 lr2-ls
> > +
> > +check ovs-vsctl -- add-port br-int vif1 -- \
> > +    set interface vif1 external-ids:iface-id=lsp1
> > +
> > +wait_for_ports_up lsp1
> > +check ovn-nbctl --wait=hv sync
> > +
> > +# the file is read once at startup so it's safe to write it
> > +# here after the first ovn-controller has started
> > +echo hv2 > ${OVN_SYSCONFDIR}/system-id-override
> > +
> > +# for some reason SSL/TLS ovsdb configuration overrides CLI, so
> > +# delete ssl config from ovsdb to give CLI arguments priority
> > +ovs-vsctl del-ssl
> > +
> > +start_virtual_controller n1 br-phys-2 br-int-2 192.168.2.1 24 geneve
> hv2 \
> > +    --pidfile=${OVS_RUNDIR}/ovn-controller-2.pid \
> > +    --log-file=${OVS_RUNDIR}/ovn-controller-2.log \
> > +    -p $PKIDIR/testpki-hv2-privkey.pem \
> > +    -c $PKIDIR/testpki-hv2-cert.pem \
> > +    -C $PKIDIR/testpki-cacert.pem \
> > +    -vvconn:dbg
> > +pidfile="$OVS_RUNDIR"/ovn-controller-2.pid
> > +on_exit "test -e \"$pidfile\" && kill \`cat \"$pidfile\"\`"
> > +
> > +check ovs-vsctl -- add-port br-int-2 vif2 -- \
> > +    set interface vif2 external-ids:iface-id=lsp2
> > +
> > +wait_for_ports_up lsp2
> > +check ovn-nbctl --wait=hv sync
> > +OVN_POPULATE_ARP
> > +
> > +check_zone_allocation() {
> > +    local ctl=$1
> > +    local prefix=$2
> > +
> > +    AT_CHECK_UNQUOTED([ovn-appctl -t $ctl ct-zone-list | cut -d ' ' -f2
> | grep -vE "$prefix[[0-9]]{2}"], [1])
> > +}
> > +
> > +check_zone_flush() {
> > +    local file=$1
> > +    local prefix=$2
> > +
> > +    AT_CHECK_UNQUOTED([grep NXT_CT_FLUSH_ZONE ${OVS_RUNDIR}/$file |
> grep -vE "zone_id=$prefix[[0-9]]{2}"], [1])
> > +}
> > +
> > +hv1_ctl="${OVS_RUNDIR}/ovn-controller.$(cat
> ${OVS_RUNDIR}/ovn-controller.pid).ctl"
> > +hv2_ctl="${OVS_RUNDIR}/ovn-controller.$(cat
> ${OVS_RUNDIR}/ovn-controller-2.pid).ctl"
> > +
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +# Re-bind both LSPs
> > +check ovs-vsctl set interface vif1 external-ids:iface-id=lsp2 \
> > +    -- set interface vif2 external-ids:iface-id=lsp1
> > +check ovn-nbctl lsp-set-options lsp1 requested-chassis=hv2 \
> > +    -- lsp-set-options lsp2 requested-chassis=hv1
> > +wait_for_ports_up
> > +check ovn-nbctl --wait=hv sync
> > +
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +# Swap GW routers.
> > +check ovn-nbctl set Logical_Router lr1 options:chassis=hv2 \
> > +    -- set Logical_Router lr2 options:chassis=hv1
> > +check ovn-nbctl --wait=hv sync
> > +
> > +# Do recompute for both controller to make that datapath swap effective.
> > +check ovn-appctl -t $hv1_ctl inc-engine/recompute
> > +check ovn-appctl -t $hv2_ctl inc-engine/recompute
> > +
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +# Remove LSPs.
> > +check ovn-nbctl --wait=hv lsp-del lsp1
> > +
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +check ovn-nbctl --wait=hv lsp-del lsp2
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +# Make the routers distributed again.
> > +check ovn-nbctl remove Logical_Router lr1 options chassis
> > +check ovn-nbctl remove Logical_Router lr2 options chassis
> > +check ovn-nbctl --wait=hv sync
> > +
> > +# Do recompute for both controller to make that datapath remove
> effective.
> > +check ovn-appctl -t $hv1_ctl inc-engine/recompute
> > +check ovn-appctl -t $hv2_ctl inc-engine/recompute
> > +
> > +check_zone_allocation $hv1_ctl 1
> > +check_zone_flush ovn-controller.log 1
> > +check_zone_allocation $hv2_ctl 3
> > +check_zone_flush ovn-controller-2.log 3
> > +
> > +OVN_CLEANUP([hv1])
> > +AT_CLEANUP
> > +])
> > --
> > 2.52.0
> >
> > _______________________________________________
> > dev mailing list
> > [email protected]
> > https://mail.openvswitch.org/mailman/listinfo/ovs-dev
> >
>
>
Regards,
Ales