On Mon, Oct 27, 2025 at 1:06 PM Dumitru Ceara <[email protected]> wrote:

> On 10/24/25 10:19 AM, Ales Musil via dev wrote:
> > Originally reported by coverity:
> >
> > *** CID 490929:         Control flow issues  (DEADCODE)
> > /utilities/ovn-ic-nbctl.c: 664             in ic_nbctl_trp_del()
> > 658         free(tr_uuid);
> > 659         if (ctx->error) {
> > 660             return;
> > 661         }
> > 662
> > 663         if (!trp) {
> >>>>     CID 490929:         Control flow issues  (DEADCODE)
> >>>>     Execution cannot reach this statement: "return;".
> > 664             return;
> > 665         }
> > 666
> > 667         icnbrec_transit_router_update_ports_delvalue(tr, trp);
> > 668         icnbrec_transit_router_port_delete(trp);
> > 669     }
> >
> > ** CID 490928:       Error handling issues  (CHECKED_RETURN)
> > /utilities/ovn-ic-nbctl.c: 739           in ic_nbctl_trp_add()
> >
> > Fixes: 89eb631d5de6 ("ic: Add Transit router support.")
> > Signed-off-by: Ales Musil <[email protected]>
> > ---
>
> Hi Ales,
>
> Thanks for the patch, looks good to me!
>
> Acked-by: Dumitru Ceara <[email protected]>
>
> Regards,
> Dumitru
>
>
Thank you Dumitru,

I went ahead and merged this into main.

Regards,
Ales