Am Mittwoch, 7. Juni 2006 17:48 schrieb Michael Weber:
> I am trying to change the timing settingss on a DS2490 adapter.
>
> The network consists of tens of Temperature sensors and some PIOs
> mainly, roughly 30 devices. It is very unstable and we are searching
> for solutions. One would be to adjust the timing (and check if the
> timings are correct as they are set by default).
>
If your network seems unreliable, first check the topology. Onewire requires
bus topology with short stubs only.
"Star" kind networks could be achieved with multiple host adapters, the
DS2842-800 host adapter or the DS2409 network coupler, if this is really
neccessary. If your cabling supports more than one pair of wires, I suppose
to change a star network into a "looped" star style instead.
Kind regard
Jan
--
Really, I'm not out to destroy Microsoft. That will just be a
completely unintentional side effect. -- Linus Torvalds
_______________________________________________
Owfs-developers mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/owfs-developers