Confimation from Maxim Support (who were very responsive).
From: Mixed Signal Apps [mailto:[email protected]]
Sent: Friday, July 20, 2012 5:20 PM
To: Alfille, Paul H.,M.D.
Subject: RE: SPR 198397 - DS1825 vs MAX31826
Hello Paul,
The MSBit (bit 7) of the DS1825 Configuration register always reports a
value of 0. And I have confirmed that the MSBit of the MAX31826's
Configuration register is always a 1. So you could use bit 7 as the
identifier bit between a DS1825 and a MAX31826.
Regards,
Precision Monitoring and Control Applications