On 07/14/2012 06:06 PM, Paul Alfille wrote: > Actually, looking closely at the datasheets, it looks like bit 7 of the > configuration register is "1" in the MAX31826 and "0" in the DS1825.
Interesting. In the datasheet I grabbed bit 7 simply shows "-". The DS1825 shows it as "0" though and also says "Bit 7 and Bit 4 of the configuration register are reserved for internal use and cannot be overwritten." However -- and this may have been what you are referring to -- the text of the MAX31826 datasheet says: "Bits [7:4] are reserved for internal use and cannot be overwritten; they return a 1 when read." Sounds like a really easy way to test whic decide it really is. Jeff ------------------------------------------------------------------------------ Live Security Virtual Conference Exclusive live event will cover all the ways today's security and threat landscape has changed and how IT managers can respond. Discussions will include endpoint security, mobile security and the latest in malware threats. http://www.accelacomm.com/jaw/sfrnl04242012/114/50122263/ _______________________________________________ Owfs-developers mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/owfs-developers