Am 29.10.2014 um 21:42 schrieb Coudy:
> Thank You Jan,
> I'll try to switch my sensors from parasitic power to regular power.
> How to enable simultaneous conversion for all chips ?
> this way ? echo 1 > /mnt/1wire/simultaneous/temperature ?
> 
Yes, this starts the temperature conversion on all buses. Wait at least
one second, after that you can read the result from the chips the usual
way - owfs will not start another conversion while a result is pending.

If you don't wait for the conversion to complete, owfs will do that for
you when reading the first chip - but in the past, there had been some
bugs with that IIRC.


Kind regards

        Jan



------------------------------------------------------------------------------
_______________________________________________
Owfs-developers mailing list
Owfs-developers@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/owfs-developers

Reply via email to