@Paul: Yes i had read that website some time ago. It made me change (then) from (mixed) star topology to my current (linear) bus. to accomodate this i followed the suggestions of the list members and used the utp-wires 4and5 for the dépard and wires 3and6 for the return. I did not try another channel since i only have one utp cat5e running from the master to the attic (and the new sensors cannot get to the master without passing through the attic); so splitting them up is not so easy
@Jan: now i'm a bit surprised, since maxim themselves talk about using cat5(e). Of course the cable is only used for 1-wire. I use a modified set of wiring based on hobbyboards. They use a pair for gnd/1-wire_data. My pinout is: 1and2 for +5v and gnd , 3and6 for return of 1-wire_data / 1-wire_gnd , 4and5 for the dépard, 7and8 not connected But i'll give it a try and use the pairs 7/8 as gnd for this (long) cable! ------------------------------------------------------------------------------ Dive into the World of Parallel Programming! The Go Parallel Website, sponsored by Intel and developed in partnership with Slashdot Media, is your hub for all things parallel software development, from weekly thought leadership blogs to news, videos, case studies, tutorials and more. Take a look and join the conversation now. http://goparallel.sourceforge.net _______________________________________________ Owfs-developers mailing list Owfs-developers@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/owfs-developers