Am 30.06.2016 um 08:30 schrieb Colin Reese:
>
> Thus, you need to know whether you are looking for a value interpreted
> as a DS1825 or as a MAX31850. Because they are indistinguishable from
> software,
>
They are distinguishable. The DS1825 configuration register bit 7 reads
always 0. The MAX31850 (and MAX31826) configuration register bit 7 reads
always 1. See the datasheets (pp. 8/13/9 resp.).
>
> So ... should I just read the scratchpad and do my own conversion, or
> can someone rewrite this?
>
We can and should. Unfortunately I have none of these devices at hand.
Kind regards
Jan
------------------------------------------------------------------------------