Greetings.

We are currently running a very old version of PacketFence(V7), which has been 
performing wonderfully for many years, and I am trying to upgrade to V15.
This is controlling our Wired and Wireless networks
I have built a new server, and have mirrored the settings on the new config to 
match the old.
The Wired infrastructure is working perfectly.
RADIUS assigns the correct VLANs there.
The Wireless is having issues.

I have been crawling the internet, and there are several other mentions of this 
issue, but no fixes or help that seems directly related.

The Radius log is displaying:

rest: ERROR: Server returned:
rest: ERROR: 
{"control:PacketFence-Authorization-Status":"allow","Reply-Message":"Switch is 
not managed by PacketFence","control:PacketFence-Request-Time":1783141953}
Rejected in post-auth: [92:27:a7:47:3a:d3] (from client 192.168.77.44/32 port 0 
cli 92:27:a7:47:3a:d3)
Login incorrect (rest: Server returned:): [92:27:a7:47:3a:d3] (from client 
192.168.77.44/32 port 0 cli 92:27:a7:47:3a:d3)

rest: ERROR: Server returned:
rest: ERROR: {"Reply-Message":"Switch is not managed by 
PacketFence","control:PacketFence-Request-Time":1783141952,"control:PacketFence-Authorization-Status":"allow"}
Rejected in post-auth: [44:00:49:86:a7:59] (from client 192.168.77.45/32 port 0 
cli 44:00:49:86:a7:59)
Login incorrect (rest: Server returned:): [44:00:49:86:a7:59] (from client 
192.168.77.45/32 port 0 cli 44:00:49:86:a7:59)

We have a pair of Ruckus SmartZone controllers in a cluster.
IPs:192.168.77.44 and 192.168.77.45

Switch config on the old system:
[192.168.77.44/31]
description=VirtualSmartZones
controllerIp=192.168.77.44,192.168.77.45
deauthMethod=RADIUS
type=Ruckus::SmartZone
radiusSecret=<Redacted>



Current Switch configs on new system:
Current Config:
[192.168.77.44/31]
radiusSecret=<Redacted>
type=Ruckus::SmartZone
description=44/31
deauthMethod=RADIUS


Have also tried:
[192.168.77.44/31]
radiusSecret=<Redacted>
type=Ruckus::SmartZone
description=44/31
deauthMethod=RADIUS
controllerIp=192.168.77.44,192.168.77.45

When saving, the system throws a "controllerIp: Value must be an IPv4 address" 
error, but it will save


Have also tried:
[192.168.77.44/32]
radiusSecret=<Redacted>
type=Ruckus::SmartZone
description=VirtualSmartZones
deauthMethod=RADIUS

[192.168.77.45/32]
radiusSecret=<Redacted>
type=Ruckus::SmartZone
description=VirtualSmartZones
deauthMethod=RADIUS
controllerIp=192.168.77.45


Ludovic Zammit had helped us years ago with a custom "SmartZone.pm" to permit 
the two controllerIP Addresses.
I do not think that is the issue here though.

Any help would be appreciated.

Thanks!

Alan Shoop
Director of Network & User Services
Technology & Library Services

Wilson College
1015 Philadelphia Ave.
Chambersburg, PA 17201
[email protected]<mailto:[email protected]>
o. 717-262-4831
f. 717-262-2032
m. 717-491-9961
www.wilson.edu<http://www.wilson.edu/>

[cid:zemailsignature-text_86a29bdd-dbc9-4d5e-9b78-d7e6ed0c533a.png]

Confidentiality Notice: This e-mail, including any attachments, is for the sole 
use of the intended recipient(s) and may contain confidential and privileged 
information. Any unauthorized review, use, disclosure, or distribution is 
prohibited. If you are not the intended recipient, please contact the sender by 
reply e-mail and destroy all copies of the original message.



_______________________________________________
PacketFence-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/packetfence-users

Reply via email to