Ok, I'm able to replicate the bug. The test file I have ( http://vtk.org/gitweb?p=VTKLargeData.git;a=tree;f=Data/WindBladeReader;h=3459e8ded59eb05796e922d90200bd4e83231df0;hb=HEAD) only has 2 time steps so I may need another set of files from you with more time steps.
Playing around with the reader in ParaView, I think it may be worse than you realize. Only the time information for the field is getting updated properly and if you go back in time steps, the blade time step either still increases or stays the same if it has hit the last time step. I need to talk to our temporal pipeline expert to figure out the proper behavior. One question though -- is there a reason that the reader doesn't return a multiblock with the 3 grids in it instead of having 3 separate output ports? I'm thinking that if the output was changed to a multiblock then these time issues would go away. Andy On Thu, Jul 7, 2011 at 10:28 PM, Sohail Shafii <sohailsha...@yahoo.com>wrote: > I believe that data set went you (related to the updates I made for the > wind blade reader)...the one with ten timesteps, should do the trick. Do > you still have it? > > Sohail > > --- On *Thu, 7/7/11, Andy Bauer <andy.ba...@kitware.com>* wrote: > > > From: Andy Bauer <andy.ba...@kitware.com> > Subject: Re: [Paraview] Interesting bug when using windbladereader and > multiple time steps > To: "Sohail Shafii" <sohailsha...@yahoo.com> > Cc: paraview@paraview.org > Date: Thursday, July 7, 2011, 7:09 PM > > > I'll take a look at it. I may need a time dependent data set if I can't > figure it out though. > > Andy > > On Thu, Jul 7, 2011 at 9:13 PM, Sohail Shafii > <sohailsha...@yahoo.com<http://mc/compose?to=sohailsha...@yahoo.com> > > wrote: > > Hi, > > I've noticed a bug when using the windbladereader; the portion of the code > that reads the blade file is one timestep behind the code that reads the > field. For instance, if one is at timestep i, the field data will > correspond with timestep "i" but the blade data will correspond with the > last timestep chosen. When a data set is opened initially both the blade > and field items are set to the initial timestep. After one starts changing > the timestep, the bug makes an appearance. > > In the code, the blade and field specify their timesteps (individually) > based on the bladeInfo and fieldInfo objects, respectively. These info > objects are related to the outputVector of requestInformation -- I wonder if > this is some kind of pipeline issue? > > Thanks, > Sohail > > _______________________________________________ > Powered by www.kitware.com > > Visit other Kitware open-source projects at > http://www.kitware.com/opensource/opensource.html > > Please keep messages on-topic and check the ParaView Wiki at: > http://paraview.org/Wiki/ParaView > > Follow this link to subscribe/unsubscribe: > http://www.paraview.org/mailman/listinfo/paraview > > >
_______________________________________________ Powered by www.kitware.com Visit other Kitware open-source projects at http://www.kitware.com/opensource/opensource.html Please keep messages on-topic and check the ParaView Wiki at: http://paraview.org/Wiki/ParaView Follow this link to subscribe/unsubscribe: http://www.paraview.org/mailman/listinfo/paraview