Steve - Thanks for the tips - I for one will start to play with it. Any pointers as to the options ? I'm using 99SE right now, and choosing (it's only a 2-layer board)
* IPC-D-356A * Top Layer * Bottom Layer * Board outline -> mechanical layer with the board outline * Conductor Traces I don't have the Adjacency Information box checked ... -- Dean Carpenter deano at areyes com 94TT :) ----- Original Message ----- From: "Steve Fenton" <[EMAIL PROTECTED]> To: <[email protected]> Sent: Wednesday, March 23, 2005 12:56 PM Subject: [PEDA] Re: HELP!! Gerber Output Contains Random Subtle Errors WithPlane Connects! > Matt (and everybody!), > > There's really no need to eyeball gerbers to check connectivity. A much > quicker and better (semi-)automated gerber check can be done as follows:- > > 1. Generate gerbers as normal. > 2. Generate an IPC-D-356 netlist from the PCB layout tool. This is generated > from the PCB file itself (*not* from the gerbers) and, in rough terms, > contains a textual description of the gerbers. IPC netlist can be generated > in DXP SP2 from CAM generation, Insert TestPoint Report (you might have to > check a few boxes first time round.) Do not generate the IPC netlist from > within Camtastic! > 3. Open a new blank Camtastic document. > 4. Import the copper layer gerbers and drill files into Camtastic. No need > to bother with paste, resist, silkscreen etc. > 5. Within Camtastic, generate a netlist from the gerber files. > 6. Within Camtastic, compare the netlist with the IPC netlist file (the one > you exported from the PCB in step 2). > > Steps 4-6 are covered in the help files under something like > 'Importing/checking Gerbers'. I'm not actually at the machine with DXP > installed, so I can't be any more detailed, but it's only been a couple of > weeks since the last time I did this. > > The PCB vs gerber netlist check will likely give you warnings about > unconnected pads (fixing holes and so on), but should otherwise match. If > not, the gerbers do match the PCB file. Simple as that. > > As an extra safety check, I always send the IPC netlist with the gerbers to > the fab house and ask them to compare their gerber-generated netlist with > the supplied IPC netlist - before they start etching! At worst case you'll > lose a day of their pre-processing time. But at least you won't waste > days/weeks making and assembling a batch of useless boards. > > I can't emphasise this point enough: the IPC netlist is generated from the > PCB design and *not* from the gerbers. As long as you remember that, its > purpose becomes obvious. > > Sorry this won't help you this time round, but it's saved my bacon several > times over the years. I got burned long ago with stitching vias which > connected Power and Ground layers together, and looked around for the > solution. Well, I asked the fab guys... > > I can't really believe more people don't supply their fab house with IPC > netlist along with gerbers. My fab house tells me I'm their only customer > who does. I guess everybody else ends up with more respins than I do! > > Sorry for my late reply. > > Cheers, > Steve > > > > Matt Polak wrote: > > > > > Hey Gang, > > > > We've come across a *major* show-stopper problem on some > > boards we just got back from our board house. For whatever reason, > > there are a few spots where DXP decided that our vias should just not > > randomly connect to the power planes their nets are assigned to. Most > > of the board is fine, but we've already found one major cluster that's > > problematic. Take a look at this... > > > > http://www.raven-systems.com/temp/missing_connections.gif > > > > As you can clearly see, when viewing the power plane > > connections in the layout editor, the interconnects show fine. When > > viewing the verbatim generated Gerbers, however (RIGHT IN DXP!) there > > are missing plane connections! The entire top set of 7 vias are not > > connected to ANY planes, whilst the bottom row are connected just fine > > where appropriate. I looked at the properties of all of the top-row > > vias, and they're just fine - nothing out of the ordinary. > > Surprisingly most of the other vias on the board (including the bottom > > row) connect just fine!! > > > > Has anyone seen this, or know of a way to have DXP scan for > > it, or fix it? We just lost a lot of time and money on this > > spin-and-assemble due to this export problem, and I have a feeling > > we'll likely be finding more of these little via issues as we continue > > to bring the board up. And worse yet, we have to do another Gerber > > generation - am I going to have to hand-check several thousand vias on > > the Gerber outputs to ensure this doesn't happen again? > > > > Honestly, this is bringing me to an absolute last straw in > > continuing to use Protel if we can't even be guaranteed consistent > > WYSIWYG output. Someone PLEASE tell me we did something wrong? I'm > > starting to lose patience with Altium's little "features" in the > > software. > > > > Frustrated as hell, > > -- Matt > > > ____________________________________________________________ > You are subscribed to the PEDA discussion forum > > To Post messages: > mailto:[email protected] > > Unsubscribe and Other Options: > http://techservinc.com/mailman/listinfo/peda_techservinc.com > > Browse or Search Old Archives (2001-2004): > http://www.mail-archive.com/[email protected] > > Browse or Search Current Archives (2004-Current): > http://www.mail-archive.com/[email protected] > > ____________________________________________________________ You are subscribed to the PEDA discussion forum To Post messages: mailto:[email protected] Unsubscribe and Other Options: http://techservinc.com/mailman/listinfo/peda_techservinc.com Browse or Search Old Archives (2001-2004): http://www.mail-archive.com/[email protected] Browse or Search Current Archives (2004-Current): http://www.mail-archive.com/[email protected]