If you put some copper void primative on a power plane, DXP will flag this
in a couple ways:

(I just tried it)

1. WARNING: Via(s)/Pad(s) touching plane splitting primitives on following
planes:
       Via (2462mil,1700mil) Top Layer to Bottom Layer:
              GND Plane

2. Processing Rule : Broken-Net Constraint ( (All) )
   Violation         Net GND
     Warning - Pad/Via touching plane splitting primitives
        Rule Violations :1


If 99SE can't do it, there's one BIG reason to upgrade!

Tony



-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Dennis Saputelli
Sent: Friday, May 13, 2005 4:42 PM
To: Protel EDA Discussion List
Subject: Re: [PEDA] Plane DRC


on a recent board i put some tracks on the power and ground planes to
control the circulation of localized currents (aka 'cuts')

after some editing and addition of some more voids (primitives consisting of
tracks and fills) to reduce capacitance under a few critical parts i almost
released it before i noticed in one area that the combination of the voids
and cuts left only a tiny area of continuity on one of the planes

caught in time, no problem, but it was all manual / visual

in discussing this with an associate he mentioned that PADs (i assume
POWERPCB) would have reported on DRC the min amount of copper required

as he is an old hand with that program and from his tone i don't think this
is something new for them

when i inquired 'what about if you put a power via over a void'?

he said of course their DRC would catch that too

Protel 99SE of course doesn't catch this and i don't think that P2004 does
either, the warning 'primitives found on plane' is pretty lame

the PADs system seems much more sophisticated in this regard as it seems
they report the no connect status on the planes in this latter situation

can anyone handy w/ PADs confirm or elaborate on this ?

Dennis Saputelli

_______________________________________________________________________
Integrated Controls, Inc.           Tel: 415-647-0480  EXT 107
2851 21st Street                    Fax: 415-647-3003
San Francisco, CA 94110             www.integratedcontrolsinc.com

 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]





 
____________________________________________________________
You are subscribed to the PEDA discussion forum

To Post messages:
mailto:[email protected]

Unsubscribe and Other Options:
http://techservinc.com/mailman/listinfo/peda_techservinc.com

Browse or Search Old Archives (2001-2004):
http://www.mail-archive.com/[email protected]
 
Browse or Search Current Archives (2004-Current):
http://www.mail-archive.com/[email protected]

Reply via email to