On Mon, Dec 8, 2025 at 1:06 PM Chao Li <[email protected]> wrote: > > I have nit comment: > > ``` > - if (ShutdownRequestPending) > + if (SlotSyncCtx->stopSignaled) > { > ereport(LOG, > - errmsg("replication slot synchronization > worker is shutting down on receiving SIGINT")); > + errmsg("replication slot synchronization > worker is shutting down because promotion is triggered")); > ``` > > In the error message, “because promotion is triggered" sound a little > redundant, can be just: > > "replication slot synchronization worker is shutting down due to promotion" >
We have a number of existing similar messages like: "logical replication parallel apply worker for subscription \"%s\" will stop because of a parameter change". So, how about: "replication slot synchronization worker will stop because promotion is triggered"? -- With Regards, Amit Kapila.