On Mon, Dec 8, 2025 at 1:06 PM Chao Li <[email protected]> wrote:
>
> I have nit comment:
>
> ```
> -       if (ShutdownRequestPending)
> +       if (SlotSyncCtx->stopSignaled)
>         {
>                 ereport(LOG,
> -                               errmsg("replication slot synchronization 
> worker is shutting down on receiving SIGINT"));
> +                               errmsg("replication slot synchronization 
> worker is shutting down because promotion is triggered"));
> ```
>
> In the error message, “because promotion is triggered" sound a little 
> redundant, can be just:
>
> "replication slot synchronization worker is shutting down due to promotion"
>

We have a number of existing similar messages like:  "logical
replication parallel apply worker for subscription \"%s\" will stop
because of a parameter change". So, how about: "replication slot
synchronization worker will stop because promotion is triggered"?

-- 
With Regards,
Amit Kapila.