> On Mar 13, 2026, at 15:12, Zhijie Hou (Fujitsu) <[email protected]> 
> wrote:
> 
>> 6 - 0001
>> 
>> start_sequence_sync runs an infinite loop to periodically sync sequences. I
>> don’t it has an auto reconnect mechanism. When something wrong happens,
>> the sync worker will exit, how can the worker
> 
> The comment seems incomplete.

Ah… just discard it. I was initially worrying about how the worker reconnect to 
primary if the connection is broken. Then I realized that once the worker 
exits, it will be restarted, then reconnect. So I tended to delete the comment, 
but not sure why I didn’t delete it completely.

Best regards,
--
Chao Li (Evan)