Tom Lane napsal(a):
Alvaro Herrera <[EMAIL PROTECTED]> writes:
Autovacuum_start probe is alone. I propose following probes for completeness:
proc-autovacuum-start
proc-autovacuum-stop
proc-bgwriter-start
proc-bgwriter-stop
Separate proc-autovacuum-worker-start and proc-autovacuum-launcher-start,
perhaps. Not that I see any usefulness in tracking autovacuum launcher
start and stop, but then if we're tracking bgwriter start and stop then
it makes the same sense.
I see no value in cluttering the system with useless probes. The worker
start/stop are the only ones here with any conceivable application IMHO.
As I answered to Alvaro. I needed to catch start of backend several times to
track call flow or attach debugger. It is possible to use some other dtrace
magic for that, but it is not easy and there is not way how to determine what
kind of process it is. For example how to measure how many writes performs
bgwriter?
Zdenek
--