Fujii Masao <masao.fu...@gmail.com> wrote:

> When I accessed the materialized view in the standby server,

> I got the following ERROR message. Looks odd to me. Is this a bug?
>
>    ERROR:  materialized view "hogeview" has not been populated
>    HINT:  Use the REFRESH MATERIALIZED VIEW command.
>
> The procedure to reproduce this error message is:
>
> In the master server:
>    CREATE TABLE hoge (i int);
>    INSERT INTO hoge VALUES (generate_series(1,100));
>    CREATE MATERIALIZED VIEW hogeview AS SELECT * FROM hoge;
>    DELETE FROM hoge;
>    REFRESH MATERIALIZED VIEW hogeview;
>    SELECT count(*) FROM hogeview;
>
> In the standby server
>    SELECT count(*) FROM hogeview;
>
> SELECT count(*) goes well in the master, and expectedly returns 0.
> OTOH, in the standby, it emits the error message.

Will investigate.

Thanks for testing!

--
Kevin Grittner
EnterpriseDB: http://www.enterprisedb.com
The Enterprise PostgreSQL Company


-- 
Sent via pgsql-hackers mailing list (pgsql-hackers@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-hackers

Reply via email to