Thanks for the response. I tried what you suggested but without any luck. I did make some progress though - by recording the same code several times and 'averaging' and experimentally cutting back. I think I now have a fairly clean set of raw codes, as follows:
name input_CD 950 825 1900 1650 1900 825 950 825 950 825 950 825 950 825 950 825 950 1650 950 825 950 825 950 89200 name Volup 950 825 950 825 950 825 1900 825 950 825 950 825 950 825 950 1650 1900 825 950 825 950 825 950 89200 name Voldown 950 825 950 825 950 825 1900 825 950 825 950 825 950 825 950 1650 1900 825 950 825 950 1650 950 89200 name PwrToggle 950 825 950 825 950 825 1900 825 950 825 950 825 950 825 950 825 950 1650 950 825 1900 825 950 89200 Of course the same approach doesn't work for the discrete power codes since I only know the decimal RC-5 data. All in all I'm very happy with my setup now, and the volume repeat works great from the SB remote. Let me know if anyone has any inspiration on the discretes; otherwise, thank you Felix for a great effort-saving tool! Best, Chris -- chriscc ------------------------------------------------------------------------ chriscc's Profile: http://forums.slimdevices.com/member.php?userid=15011 View this thread: http://forums.slimdevices.com/showthread.php?t=42208 _______________________________________________ plugins mailing list [email protected] http://lists.slimdevices.com/lists/listinfo/plugins