Fort Calhoun has used Diversified Technologies Services to do underwater power wash and vacuum Technologies robot cleaning in SWIRT , Transfer Canal, and Lower Cavity deconning in 09 outage. Had a lot of legacy contamination from bad fuel was involved. 2011 outage we are done with the Transfer Canal and will do Lower Cavity in a week. 5000 PSI pressure, a tri-nuke vacuum and a camera attached to robot. Talking about attaching a detector probe for our next campaign. Started with dose rates @ 1000 Rem/Hr and after second decon of Transfer Canal general area dose rates 10-100 Mr/Hr. Contact me at 402-533-7194.
Radwaste Supervisor Marlyn Anderson From: [email protected] [mailto:[email protected]] On Behalf Of Michael C Wynn Sent: Wednesday, May 11, 2011 1:27 PM To: [email protected] Subject: Powernet: Underwater Vacuum Technologies Need your help, Millstone Power Station is currently looking to upgrade our underwater vacuuming capabilities. We currently using a Tri-Nuc 260 or 600 and are working with an older robot (parts are a challenge) or a series of poles (2" cam-luc aluminum) attached to a vacuum head. Does anyone have suggestions on a better technique or latest robot technologies you've had success with? Thank you for your help. Michael C. Wynn Supervisor Radiological Analysis Millstone Power Station Bldg. 437/2 Rope Ferry Road Waterford, CT 06370 Office: (860) 447-1791 Ext. 4815 Fax: (860) 444-4241 http://www.dom.com/ CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you. This e-mail contains Omaha Public Power District's confidential and proprietary information and is for use only by the intended recipient. Unless explicitly stated otherwise, this e-mail is not a contract offer, amendment, nor acceptance. If you are not the intended recipient you are notified that disclosing, copying, distributing or taking any action in reliance on the contents of this information is strictly prohibited.