Fort Calhoun has used Diversified Technologies Services to do underwater power 
wash and vacuum Technologies  robot cleaning in SWIRT , Transfer Canal, and 
Lower Cavity deconning in 09 outage. Had a lot of legacy contamination from bad 
fuel was involved. 2011 outage we are done with the Transfer Canal and will do 
Lower Cavity in a week. 5000 PSI pressure, a tri-nuke vacuum and a camera 
attached to robot. Talking about attaching a detector probe for our next 
campaign. Started with dose rates @ 1000 Rem/Hr and after second decon of 
Transfer Canal general area dose rates 10-100 Mr/Hr. Contact me at 402-533-7194.

Radwaste Supervisor
Marlyn Anderson

From: [email protected] [mailto:[email protected]] On Behalf Of 
Michael C Wynn
Sent: Wednesday, May 11, 2011 1:27 PM
To: [email protected]
Subject: Powernet: Underwater Vacuum Technologies


Need your help, Millstone Power Station is currently looking to upgrade our 
underwater vacuuming capabilities.  We currently using a Tri-Nuc 260 or 600 and 
are working with an older robot (parts are a challenge) or a series of poles 
(2" cam-luc aluminum) attached to a vacuum head.  Does anyone have suggestions 
on a better technique or latest robot technologies you've had success with?  
Thank you for your help.


Michael C. Wynn
Supervisor Radiological Analysis
Millstone Power Station
Bldg. 437/2
Rope Ferry Road
Waterford, CT 06370
Office: (860) 447-1791 Ext. 4815
Fax: (860) 444-4241
http://www.dom.com/



CONFIDENTIALITY NOTICE: This electronic message contains information which may 
be legally confidential and/or privileged and does not in any case represent a 
firm ENERGY COMMODITY bid or offer relating thereto which binds the sender 
without an additional express written confirmation to that effect. The 
information is intended solely for the individual or entity named above and 
access by anyone else is unauthorized. If you are not the intended recipient, 
any disclosure, copying, distribution, or use of the contents of this 
information is prohibited and may be unlawful. If you have received this 
electronic transmission in error, please reply immediately to the sender that 
you have received the message in error, and delete it. Thank you.

This e-mail contains Omaha Public Power District's confidential and proprietary 
information and is for use only by the intended recipient.  Unless explicitly 
stated otherwise, this e-mail is not a contract offer, amendment, nor 
acceptance.  If you are not the intended recipient you are notified that 
disclosing, copying, distributing or taking any action in reliance on the 
contents of this information is strictly prohibited.

Reply via email to