STP uses 2000 ncpm on a standard frisker fixed contamination, no detectable by smear. No limit for tool monitor, total activity.
Regards, Leonard Earls 361-972-7759 ________________________________ From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Monday, July 25, 2011 17:18 To: [email protected] Subject: Powernet: Limits on contamination for hot tools? This question has probably been asked and answered before but I'm wondering what you'all use for acceptable limits for contamination on hot tools (not those specifically designated for containment). I assume no detectable smearable (< 1k dpm/100 cm2) but how about fixed? 5k dpm/probe area? Any specific criteria for what total activity the tool exhibits if placed in a SAM? Such as 20 nCi (~50k dpm)? Thanks, Eric (San Onofre HP Tech Support) Eric M. Goldin, CHP Southern California Edison <[email protected]> ----------------------------------- Powernet - a service of the Health Physics Society Power Reactor Section Powernet archives at http://www.mail-archive.com/[email protected]/ Reply to: [email protected] If Questions, contact Mike Russell, CHP at [email protected]