Watts Bar same as the Ferry.
From: [email protected] [mailto:[email protected]] On Behalf Of Creamer, Charles E Sent: Friday, August 26, 2011 11:15 AM To: [email protected] Subject: Powernet: DMC-2000s Response Check Frequency Browns Ferry currently conducts a quarterly response check on our DMC2000S dosimeters. This is in addition to our yearly calibration. One of our new employees that came from another utility claims we are out of line with the rest of the industry on this as they just did a yearly response check. What frequency do you response check your electronic dosimeters? ___________________________ Chuck Creamer Charles E. Creamer Health Physicist Tennessee Valley Authority Browns Ferry Nuclear Plant P.O. Box 2000 (Mail Stop NAB-1G-BFN) Decatur, Al. 35609-2000 Phone: 256-729-2983 Fax: 256-729-3101 Pager: 1-800-323-4853, pin 30-053 mailto:[email protected] <mailto:[email protected]>
<<image001.jpg>>