In comparison, here's what I have gathered so far ...


F&J Econoair L-12P

Radeco RAD-Pro5

Gilian GilAir Plus

Max Flow

12 LPM

5 LPM

5 LPM

Flow Rate

3 - 12 LPM

800 - 5000 cc/min

20 - 5000 cc/min

Battery

NiMH

NiMH

NiMH, optional alkaline battery pack, or DC Power

Charge Time

Standard charger 16 hrs, also available 1 hr recharger

4 hrs

Under 3.5 hrs

Min. Run

8 hrs

8 hrs

8 hrs

Size (inches)

7 x 4.25 x 2.5

5 x 3 x 2

4.3 x 2.4 x 2.4

Weight

31 oz

22 oz

20.5 oz


________________________________
From: [email protected] [mailto:[email protected]] On Behalf Of 
Barber, Jerry
Sent: Monday, November 07, 2011 10:51 AM
To: '[email protected]'
Subject: Powernet: RE: Lapel Air Sampling

At Robinson we currently use MSA Escorts and as well as Gillian Lapels.  We 
sample at 3 lpm which is highest rate we can for these pumps.  Based on what I 
have recently heard, I would like to have the F&J Lapels that sample as 
standard man breathing rate of 20 lpm.  I would like to hear from some plants 
that are using these myself - battery life would be only drawback I can think 
of off hand....

From: [email protected] [mailto:[email protected]] On Behalf Of 
Barnby, Monica
Sent: Monday, November 07, 2011 11:41 AM
To: '[email protected]'
Subject: Powernet: Lapel Air Sampling


All,
Do you use personal lapel air samplers?
If so, what make/model? Advantages/disadvantages?
At DCPP we do not use personal lapel samplers.
Thanks!

Reply via email to