Thanks to everyone for their responses; I now realize my question was poorly worded. I was targeting software programs used to evaluate internal dose in response to positive whole body counts, not EP Dose Assessment. Does anyone have experience with a good software program for this purpose?
FYI - for EP Dose Assessment Activities, at Ginna we use a program called EOF8 (I believe it is homegrown) combined with Rascal. Thanks, -Steve Stephen J Holmes, PE Sr. Plant Health Physicist Constellation Energy - RE Ginna Plant [email protected] 585-771-3577; 585-545-1661 (cell) From: [email protected] [mailto:[email protected]] On Behalf Of Benjy P Bertossi Sent: Thursday, March 15, 2012 11:22 AM To: [email protected] Subject: Re: Powernet: RE: Software for Dose Assessment Fermi - RADDOSE Benjy Bertossi Fermi2 - RP Supervisor 734-586-4935 [email protected] [cid:[email protected]]"Johnson, Graham T" ---03/15/2012 09:58:50 AM---Duke Energy asked this question a few months ago. Based on that Powernet and some calls, we develop From: "Johnson, Graham T" <[email protected]> To: "[email protected]" <[email protected]> Date: 03/15/2012 09:58 AM Subject: Powernet: RE: Software for Dose Assessment Sent by: [email protected] ________________________________ Duke Energy asked this question a few months ago. Based on that Powernet and some calls, we developed the list below. Anyone who believes their info is not correct, please weigh in. Thanks, Graham Johnson Duke Raddose SCE Raddose Palo Verde Raddose SONGS Raddose STP STAMPEDE (in house software) Ft. Calhoun EAGLE (in house software) Columbia Rascal (moving to URI soon) Exelon URI Entergy URI Progress Rascal 3.0.5 (moving to URI soon) Dominion MIDAS Beaver Valley MIDAS DC Cook MIDAS Diablo MIDAS VC Summer MIDAS (switching to URI soon) From: [email protected] [mailto:[email protected]] On Behalf Of Holmes, Stephen J Sent: Thursday, March 15, 2012 9:09 AM To: '[email protected]' Subject: Powernet: Software for Dose Assessment I am benchmarking what software other plants are using for dose assessment (and other Health Physics applications). We are looking to upgrade and would appreciate any feedback and recommendations. At Ginna we are currently using: Internal Dose Assessment INDOS Internal Dosimetry Code, Version 1.0, 1987, (c) 1987 Skrable Enterprises Inc. This is a DOS-based program which our IT tells us does not interface well with Windows 7 and requires a dot matrix printer to print the output. Skin Dose Assessment Varskin MOD2 I know that there are newer versions of Varskin available, but our procedures currently are based on MOD2. Shielding/Dose to Curie Calculations MegaShield, WMG Inc Thanks, -Steve Stephen J Holmes, PE Sr. Plant Health Physicist Constellation Energy - RE Ginna Plant [email protected] 585-771-3577; 585-545-1661 (cell) >>> This e-mail and any attachments are confidential, may contain legal, professional or other privileged information, and are intended solely for the addressee. If you are not the intended recipient, do not use the information in this e-mail in any way, delete this e-mail and notify the sender. -IP2
<<inline: image001.gif>>