Watts Bar replies:

 

During doffing process, after outer shoe covers and gloves are removed
workers takes dosimeter from whirl-pack and places immediately on SOP.
After the worker exits the area he picks up dosimeter and goes to the
frisker / PCM.

 

 

 

From: [email protected] [mailto:[email protected]] On Behalf
Of Seabock, Mike
Sent: Monday, March 19, 2012 10:31 AM
To: '[email protected]'
Cc: Hawker, Mark G.
Subject: Powernet: RE: Benchmark on EDs left at SOPs

 

HNP - during undress process, after outer shoe covers and gloves are
removed workers takes dosimeter from whirl-pack and places immediately
on lanyard. Additional controls include turnstiles at the CA boundary in
order for dosimeter not to be left. 

 

Michael Seabock 
Lead Radiation Control Specialist - ALARA
Harris Nuclear Plant 
919.362.2808 (
[email protected] 

 

 

 

 

From: [email protected] [mailto:[email protected]] On Behalf
Of Huneycutt, Scott
Sent: Monday, March 19, 2012 10:15 AM
To: '[email protected]'
Cc: Hawker, Mark G.
Subject: Powernet: Benchmark on EDs left at SOPs

 

A quick benchmark:

 

What are sites doing to make sure persons exiting high-traffic
Contamination Areas do not leave their Electronic Dosimeters at the
step-off pad or in their PCs?  

 

Are sites using engineering controls such as smart turnstiles or
swing-arms so an ED is required to exit the area (outside the CA)?

 

EDs are required to log out of the RCA.  An ED left at the CA exit might
not be discovered until the worker is ready to log out of the RCA.  This
means they are not monitored by self-reading, alarming dosimeters during
transit to exit (or until discovery).  Also, the EDs might be mixed up
in plant laundry before it can be retrieved; their dose history for the
that RCA entry would therefore be lost.

 

Your response is appreciated.

 

Scott Huneycutt 

Xcel Energy | Responsible By Nature

Senior Health Physicist

Monticello Nuclear Generating Plant

2807 West County Road 75, Monticello, MN 55362

P: 763.295.1380   F:  763.295.1225

E: [email protected] <mailto:[email protected]> 
________________________________________________

XCELENERGY.COM <http://www.xcelenergy.com/> 

Please consider the environment before printing this email

 

Reply via email to