SONGS uses a source made from an actual air sample so the instrument efficiency is corrected for self absorption/transmission/ attenuation.
John Joyce



From:        "Barnby, Monica" <[email protected]>
To:        "'[email protected]'" <[email protected]>
Date:        04/04/2012 09:06 AM
Subject:        Powernet: Air sample alpha analysis
Sent by:        [email protected]




 
Diablo Canyon wants to know ..
What (if any) attenuation / transmission / self absorption factor is used for alpha analysis of particulate air samples?
 
Any input will be appreciated!
Monica Barnby
PG&E Diablo Canyon
Health Physicist
805 545 3566
 
 
 