San Onofre:   We have a SAM adjacent to each CTMT/SFP dedicated to harness self-surveys.  Toolroom-type setpoints.  Workers reqd. to self-survey prior to each use.

Also often require papers under harnesses.  PC sweatthru can cause PCEs even when harnesses are very low level.  Harness rubs.....


Mark Lewis
Health Physics Division Manager
San Onofre Nuclear Generating Station (D1N)

Work:  (949) 368-7687
[email protected]





From:        <[email protected]>
To:        <[email protected]>
Date:        07/20/2012 09:32 AM
Subject:        Powernet: RE: What are the best practices for reducing the number of PCEs contributed to wearing fall protection in the RCA?
Sent by:        [email protected]




Palo Verde provides the following response:
 
·         Not allowed to be dropped / placed / stored on the floor.  
 
·         Surveyed after each use and hung on designated racks.  If a safety harnesses exceeding 60k dpm direct frisk they are removed from service and treated as radioactive waste.
 
·         Once a Safety harnesses is used in an HCAs it cannot be used in a lower contamination area again.
 
 
**********************************************************************
Seth J. Kanter, CHP, RRPT
Sr. Health Physicist
Palo Verde Nuclear Generating Station
Mail Sta. 7397
5801 S. Wintersburg Rd.
Tonopah, AZ 85354
Phone (623) 393-3130

Cell (602) 376-7131 or (602) 402-5764
Fax (623) 393-1853
Unless otherwise noted, all opinions are my own

Liviu Librescu

**********************************************************************

 
 
 
From: [email protected] [mailto:[email protected]] On Behalf Of Erik P Simon
Sent:
Thursday, July 19, 2012 6:07 PM
To:
'[email protected]'
Subject:
Powernet: FW: What are the best practices for reducing the number of PCEs contributed to wearing fall protection in the RCA?

 
 
 
From: Erik P Simon (Generation - 3)
Sent:
Thursday, July 19, 2012 8:47 PM
To:
'[email protected]'
Subject:
What are the best practices for reducing the number of PCEs contributed to wearing fall protection in the RCA?

 
Surry Power Station is interested in what efforts are your stations taking to reduce personnel contamination events that have resulted from wearing fall protection in the RCA?
Thanks in advance,
Erik
 
Erik Simon
Health Physics Shift Supervisor
Radiation Protection, Surry Power Station
 
Dominion Generation
Phone:  757-365-2672; Internal: 8-798-2672
Pager:  800-272-5643-3299; E-mail: [email protected]
 
 

CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.

--- NOTICE ---

This message is for the designated recipient only and may contain confidential, privileged or proprietary information.  If you have received it in error, please notify the sender immediately and delete the original and any copy or printout.  Unintended recipients are prohibited from making any other use of this e-mail.  Although we have taken reasonable precautions to ensure no viruses are present in this e-mail, we accept no liability for any loss or damage arising from the use of this e-mail or attachments, or for any delay or errors or omissions in the contents which result from e-mail transmission.