Surry Power Station response: we have an empty pocket policy that was enacted 
originally to prevent unauthorized equipment from exiting the RCA, i.e. marked 
tools that could be placed into a back pocket ( we mark tools purple) from 
making it to non-RCA areas. Our current policy precludes placement of hardhats 
in the SAM. Workers wear them out through the ARGOS.
Regards,
Erik

Erik Simon
Health Physics Shift Supervisor
Radiation Protection, Surry Power Station

Dominion Generation
Phone:  757-365-2672; Internal: 8-798-2672
Pager:  800-272-5643-3299; E-mail: [email protected]



-----Original Message-----
From: [email protected] [mailto:[email protected]] On Behalf Of 
Johnson, Graham T
Sent: Tuesday, January 29, 2013 8:35 PM
To: [email protected]
Subject: Powernet: Hard Hats at RCA Exit

Duke Energy would like to know what policy other sites have for hard hats at 
the RCA exit.  Do you require employees to put them in the SAM with other 
personal hand carried items or do you have employees wear the hard harts 
through the whole body monitor(s) (Argos/PCM/Portal)

Duke's current "empty pockets" policy requires hard hats be monitored through 
the SAM and we are interested in what other policies are being used and what 
technical justification, if any, the policy based on.

Thanks,
Graham Johnson
-----------------------------------
Powernet - a service of the Health Physics Society Power Reactor Section

Powernet archives at http://www.mail-archive.com/[email protected]/

Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]
CONFIDENTIALITY NOTICE:  This electronic message contains
information which may be legally confidential and/or privileged and
does not in any case represent a firm ENERGY COMMODITY bid or offer
relating thereto which binds the sender without an additional
express written confirmation to that effect.  The information is
intended solely for the individual or entity named above and access
by anyone else is unauthorized.  If you are not the intended
recipient, any disclosure, copying, distribution, or use of the
contents of this information is prohibited and may be unlawful.  If
you have received this electronic transmission in error, please
reply immediately to the sender that you have received the message
in error, and delete it.  Thank you.
-----------------------------------
Powernet - a service of the Health Physics Society Power Reactor Section

Powernet archives at http://www.mail-archive.com/[email protected]/

Reply to: [email protected]
If Questions, contact Mike Russell, CHP at [email protected]

Reply via email to