Seth, We use Nuclear Power Outfitters (NPO) SAR bubble hoods. Our grade D air is normally supplied by station service air. We use a rental company to provide a regulator system (includes filters and monitors) in conjunction with our service air. Occasionally, we will use a rental compressor and provide additional sampling to ensure it meets the breathing air requirements.
Barbara J. Thompson North Anna Power Station 1022 Haley Drive Mineral, Va 23117 Nuclear Specialist Email: [email protected]<mailto:[email protected]> Phone: 540-894-2638 From: [email protected] [mailto:[email protected]] On Behalf Of [email protected] Sent: Tuesday, February 05, 2013 3:54 PM To: [email protected] Cc: [email protected] Subject: Powernet: Bubble Hoods and Breathing Air Supply Palo Verde currently uses the LANCS Air Fed (Bubble) Hood for making internal Steam Generator entries. Until recently, we used the plant's service air system to supply breathing air; however, due to a plant modification this was no longer available for use and we have subsequently replaced the plant system with temporary breathing air compressors that are external to the Containment Building. Palo Verde would like to know the following: If you use bubble hoods, what brand / manufacture do you use? What is your source for grade D breathing air, e.g., plant system, compressor, etc.? Thanks in advance, Seth --- NOTICE --- This message is for the designated recipient only and may contain confidential, privileged or proprietary information. If you have received it in error, please notify the sender immediately and delete the original and any copy or printout. Unintended recipients are prohibited from making any other use of this e-mail. Although we have taken reasonable precautions to ensure no viruses are present in this e-mail, we accept no liability for any loss or damage arising from the use of this e-mail or attachments, or for any delay or errors or omissions in the contents which result from e-mail transmission. CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.