Hope Creek Generating Station (BWR) would like to know what your site uses for
cavity walls and dryer separator pit walls, floor, lower internals or upper
internals walls and floor decontamination.

Does your site use strippable coating? No
The wall WEPA? Used to but not anymore
Is the cavity stainless or carbon steel?  Stainless


1.         What method do you use (hydrolasing, foam, strippable paint etc). - 
Apply Syntec NOC to walls and cavity floor with a pressurized foam applicator. 
Pressure wash and scrub with scotch brite.

2.         Do you do this in house or contract out - In house using in house 
and contractor personnel.

3.         Do you have your own decontamination force. - Two personnel at this 
time.

4.         Scheduled duration. 8 hours

5.         Post decontamination smearable contamination levels. - Goal is < 
100K dpm/100cm2 which is usually obtained.



[email protected]<mailto:[email protected]>


Susanne Ziegler
PSEG Radiation Protection
Hope Creek Generating Station
PO Box 236, MC H05
Hancocks Bridge, NJ 08038
856-339-5143
FAX 856-339-3336

Gadugi-working together for a common good




________________________________

The information contained in this e-mail, including any attachment(s), is 
intended solely for use by the named addressee(s). If you are not the intended 
recipient, or a person designated as responsible for delivering such messages 
to the intended recipient, you are not authorized to disclose, copy, distribute 
or retain this message, in whole or in part, without written authorization from 
PSEG. This e-mail may contain proprietary, confidential or privileged 
information. If you have received this message in error, please notify the 
sender immediately. This notice is included in all e-mail messages leaving 
PSEG. Thank you for your cooperation.

Reply via email to