Salem/Hope Creek

PSEG Nuclear uses ProRad 5.44 (Sentinel's mother) and requires the DLR/TLD and 
ED to sign out of the RCA


Susanne Ziegler
PSEG Radiation Protection
Hope Creek Generating Station
PO Box 236, MC H05
Hancocks Bridge, NJ 08038
856-339-5143
FAX 856-339-3336

Gadugi-working together for a common good






From: [email protected] [mailto:[email protected]] On Behalf Of 
BENSON, RICHARD
Sent: Monday, April 21, 2014 12:05 PM
To: [email protected]
Subject: Powernet: RE: Worker ID at RWP log out

At Grand Gulf workers are required to scan their DLR/TLD during the log out 
process. We use Sentinel which validates that individual was issued that ED.


Rich Benson

Superintendent, Radiation Protection

Grand Gulf Nuclear Station

Port Gibson, MS  39150

Office 601-437-2150

Cell 601-630-5749

________________________________
From: [email protected]<mailto:[email protected]> 
[mailto:[email protected]] On Behalf Of Creamer, Charles E
Sent: Monday, April 21, 2014 10:04 AM
To: '[email protected]'
Subject: Powernet: Worker ID at RWP log out

When workers at your utility sign out of an RWP does your station use a 
secondary means of identifying the worker.  Currently BFN only uses the ED in 
the workers possession at sign out to identify the worker.  The question that 
arose was how do we know a worker signed out with the same ED they signed in 
with.

Examples of secondary identification methods could be scanning a TLD. manually 
entering a plant ID or some other method.

If you are using a means of secondary identification at the RWP exit, what 
method and software are you using?

BFN currently uses HIS-20.
Chuck Creamer
Charles E. Creamer
Health Physicist
Tennessee Valley Authority
Browns Ferry Nuclear Plant
P.O. Box 2000 (Mail Stop NAB-1G-BFN)
Decatur, Al. 35609-2000
Phone: 256-729-2983
Fax:  256-729-3101
Pager: 1-800-323-4853, pin 30-053
mailto:[email protected]

REMEMBER - You don't know what you don't know

This electronic message transmission contains information which may be TVA 
SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL. Any misuse or unauthorized 
disclosure can result in both civil and criminal penalties. If you are not the 
intended recipient, be aware that any disclosure, copying, distribution or use 
of the content of this information is prohibited. If you have received this 
communication in error, please notify me immediately by email and delete the 
original message.



-----------------------------------------
The information contained in this e-mail, including any
attachment(s), is intended solely for use by the named
addressee(s).  If you are not the intended recipient, or a person
designated as responsible for delivering such messages to the
intended recipient, you are not authorized to disclose, copy,
distribute or retain this message, in whole or in part, without
written authorization from PSEG.  This e-mail may contain
proprietary, confidential or privileged information. If you have
received this message in error, please notify the sender
immediately. This notice is included in all e-mail messages leaving
PSEG.  Thank you for your cooperation.

Reply via email to