Bob, Comanche Peak response
If facial contamination is present around the nose and mouth, obtain nasal smears and direct worker to report to dosimetry for a whole body count. If nasal smears are > 100 ncpm as determined by a GM pancake detector, send the sample to Chemistry for gamma analysis and document. Shari Mosty Sr. Health Physicist Comanche Peak Nuclear Power Plant 6322 N. FM 56 Glen Rose, Texas 76043 254.897.5204 [email protected] From: [email protected] [mailto:[email protected]] On Behalf Of Beckham, Bob Sent: Tuesday, August 12, 2014 2:08 PM To: [email protected] Subject: Powernet: Nasal Swabs Duke Energy would appreciate any response you can provide on the following question. Thanks in advance. In responding to a potential uptake of radioactive material, do site procedures allow, or not allow, for collecting nasal swabs on affected personnel? Bob Beckham | Lead Scientist | Fleet Scientific Services | Radiation Protection | Duke Energy Carolinas, LLC 526 S. Church St. | Mail Stop EC07F | Charlotte, NC 28202 | 704-382-6713 office | 704-453-6002 cell [cid:471a717e-74d5-43f7-b4bf-b02520e1c1ee] Confidentiality Notice: This email message, including any attachments, contains or may contain confidential information intended only for the addressee. If you are not an intended recipient of this message, be advised that any reading, dissemination, forwarding, printing, copying or other use of this message or its attachments is strictly prohibited. If you have received this message in error, please notify the sender immediately by reply message and delete this email message and any attachments from your system.