Chuck,

Here is a copy of our Decon Standard for interfacing with contaminated area 
boundaries.  Send me a note if you have any questions or need additional 
information.


Barbara J. Thompson

North Anna Power Station

1022 Haley Drive

Mineral, Va 23117

Nuclear Specialist

Email:  [email protected]<mailto:[email protected]>

Phone:  540-894-2638


From: [email protected] [mailto:[email protected]] On Behalf Of 
Creamer, Charles E
Sent: Saturday, March 28, 2015 1:47 PM
To: '[email protected]'
Subject: Powernet: Personnel Contamination Monitoring

We are looking to develop some procedure guidance for performing contamination 
monitoring of personnel pulling trash and laundry in multiple contaminated 
areas or chemistry pulling samples in multiple sample hoods.   Many of these 
areas are not near a contamination monitor and it is not possible to put one in 
all areas where this situation could occur.

Do you allow hand and foot monitoring before exiting an elevation, or require 
the workers proceed to the contamination monitors each exit.

Any input or procedural examples would be appreciated

Chuck Creamer
Charles E. Creamer
Health Physicist
Tennessee Valley Authority
Browns Ferry Nuclear Plant
P.O. Box 2000 (Mail Stop NAB-1G-BFN)
Decatur, Al. 35609-2000
Phone: 256-729-2983
Fax:  256-729-3101
Pager: 1-800-323-4853, pin 30-053
mailto:[email protected]


This electronic message transmission contains information which may be TVA 
SENSITIVE, TVA RESTRICTED or TVA CONFIDENTIAL. Any misuse or unauthorized 
disclosure can result in both civil and criminal penalties. If you are not the 
intended recipient, be aware that any disclosure, copying, distribution or use 
of the content of this information is prohibited. If you have received this 
communication in error, please notify me immediately by email and delete the 
original message.




CONFIDENTIALITY NOTICE:  This electronic message contains information which may 
be legally confidential and or privileged and does not in any case represent a 
firm ENERGY COMMODITY bid or offer relating thereto which binds the sender 
without an additional express written confirmation to that effect.  The 
information is intended solely for the individual or entity named above and 
access by anyone else is unauthorized.  If you are not the intended recipient, 
any disclosure, copying, distribution, or use of the contents of this 
information is prohibited and may be unlawful.  If you have received this 
electronic transmission in error, please reply immediately to the sender that 
you have received the message in error, and delete it.  Thank you.

Attachment: Decon Standard 01 CA Interface 2004.doc
Description: Decon Standard 01 CA Interface 2004.doc

Reply via email to