Please have a look at the same topic being discussed last month https://lists.proxmox.com/pipermail/pve-user/2023-June/017117.html

TL;DR: VROC is usually a "fake raid" and not a real HW RAID. It only tells the OS what software RAID to create. On Linux that would typically be MD-RAID.

Proxmox VE does not ship MD Raid and therefore, those disks will still be visible as single disks.

Cheers,
Aaron

On 7/26/23 13:44, Joseph John wrote:
Dear All,
We are trying to install ProxMox 8 on Supermicro x12dpu-6 , with Intel VROC
RAID Controller , we have configured  two SSD in RAID 1 , from the BIOS in
hardware level  and  raid volume is created, but when coming to the proxmox
setup , the installation step is not showing the RAID volume, but it shows
the physical disk separately .
Like get guidance  on how Proxmox treats Intel VROC RAID Controller and the
possible next step
Thanks


Thanks
Joseph John
_______________________________________________
pve-user mailing list
[email protected]
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user




_______________________________________________
pve-user mailing list
[email protected]
https://lists.proxmox.com/cgi-bin/mailman/listinfo/pve-user

Reply via email to