28.01.2024 23:22, Sven Schnelle :
When the maximum count of SCRIPTS instructions is reached, the code
stops execution and returns, but fails to decrement the reentrancy
counter. This effectively renders the SCSI controller unusable
because on next entry the reentrancy counter is still above the limit.

This bug was seen on HP-UX 10.20 which seems to trigger SCRIPTS
loops.

Cc: qemu-stable@

/mjt